Performance of light-emitting diode fluorescence microscope for diagnosis of tuberculosis
Open Access
- 1 September 2013
- journal article
- Published by Medknow in International Journal of Mycobacteriology
- Vol. 2 (3) , 174-178
Abstract
Background: Fluorescence microscopy (FM) over the years has shown the potential for increasing the performance of microscopy. The present study was aimed to access the performance of the LED microscope for the detection of acid fast bacilli in a tuberculosis (TB) endemic country. Methods: The study was conducted at a National Reference Laboratory (NRL) in New Delhi, India. Sputum samples were collected from suspected TB patients. Each sample was processed with Auramine O and ZN methods. Auramine O stained smears were evaluated using two different excitatory light sources (MVP and LED); and ZN stained smears were examined under light microscope. The mean time required to read the smears with different modalities was recorded. Bacterial cultures provided the reference standard. Results: A total of 200 patients were included in this study. Sensitivity and specificity for the LED assessment, MVP assessment and light microscopy were 83.1% and 82.4%, 78.5% and 87.5% and 81.6% and 83.5%, respectively. Mean reading time was approximately three times faster than ZN microscopy. The mean time to read a negative smear was 2 min with fluorescence microscopy and 5 min with light microscopy with time savings of 60%. Conclusion: Although the use of LED-FM only marginally increased sensitivity, the considerable time saving ability combined with very good acceptance and ease of use makes it a reliable alternative to other conventional methods available.Keywords
This publication has 9 references indexed in Scilit:
- New Policies, New Technologies: Modelling the Potential for Improved Smear Microscopy Services in MalawiPLOS ONE, 2009
- Use of Light‐Emitting Diode Fluorescence Microscopy to Detect Acid‐Fast Bacilli in SputumClinical Infectious Diseases, 2008
- Bleach Sedimentation: An Opportunity to Optimize Smear Microscopy for Tuberculosis Diagnosis in Settings of High Prevalence of HIVClinical Infectious Diseases, 2008
- Improvement of tuberculosis case detection and reduction of discrepancies between men and women by simple sputum-submission instructions: a pragmatic randomised controlled trialThe Lancet, 2007
- Fluorescence microscopy for tuberculosis diagnosisThe Lancet Infectious Diseases, 2007
- Fluorescence microscopy for tuberculosis diagnosisThe Lancet Infectious Diseases, 2007
- Fluorescence versus conventional sputum smear microscopy for tuberculosis: a systematic reviewThe Lancet Infectious Diseases, 2006
- EFFICACY OF FLUOROCHROME STAIN IN THE DIAGNOSIS OF PULMONARY TUBERCULOSIS CO-INFECTED WITH HIVIndian Journal of Medical Microbiology, 2005
- Efficacy of fluorochrome stain in the diagnosis of pulmonary tuberculosis co-infected with HIVIndian Journal of Medical Microbiology, 2005