A monitoring and physiological control system for determining aortic valve closing with a ventricular assist device
Open Access
- 4 February 2014
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 46 (3) , 356-360
Abstract
Real-time monitoring of the aortic valve function and the loading state of the left ventricle (LV) during mechanical circulatory support is essential. Therefore, we developed a system that determines accurately the aortic valve closing moment based on integrals derived from the pump inlet pressure and the pump power [pressure-power area (PPA)]. A Deltastream diagonal pump was implanted in 10 healthy Rhoen sheep. Changes in ventricular volume and pressure in different assist levels were measured by a conductance catheter placed in the LV and were correlated with intrinsic pump signals, motor power, voltage and current. Measurements were obtained in the state of normal as well as decreased left ventricular contractility induced by β-blockers. Complete datasets were obtained in seven animals. The PPA-feedback signal reached its maximum at the speed of aortic valve closing. This was validated by pressure-volume (PV)-catheter measurements both at the baseline and in the state of decreased contractility. In both cases, zero-crossing occurred at the point of aortic valve closing speed. With this trial, we deliver the experimental basis for the development of an automatic feedback controller that would allow periodic speed changes in accordance with the loading state of the native ventricle and the opening state of the aortic valve. This would deliver real-time data to treating physicians and enable the establishment of a standard weaning protocol.Keywords
This publication has 9 references indexed in Scilit:
- Pulsed or continuous flow in long-term assist devices: a debated topicTransplantation Reviews, 2012
- Improved left ventricular unloading and circulatory support with synchronized pulsatile left ventricular assistance compared with continuous-flow left ventricular assistance in an acute porcine left ventricular failure modelThe Journal of Thoracic and Cardiovascular Surgery, 2010
- Is Pulsatile Blood Flow No Longer Essential?Circulation, 2009
- Reverse remodeling during long-term mechanical unloading of the left ventricleJournal of Molecular and Cellular Cardiology, 2007
- Effect of Left Ventricular Assist Device Outflow Conduit Anastomosis Location on Flow Patterns in the Native AortaASAIO Journal, 2006
- Reverse remodeling following insertion of left ventricular assist devices (LVAD): A review of the morphological and molecular changesCardiovascular Research, 2005
- Left Ventricular Unloading with an Assist Device Results in Receptor Relocalization as well as Increased Beta-Adrenergic Receptor Numbers: Are These Changes Indications for Outcome?Journal of Cardiac Surgery, 2005
- Comparison of Right and Left Ventricular Responses to Left Ventricular Assist Device Support in Patients With Severe Heart FailureCirculation, 2001
- Left ventricular echocardiographic and histologic changes: Impact of chronic unloading by an implantable ventricular assist deviceJACC, 1996