Real-time experimental validation of a novel semi-active control scheme for vibration mitigation
- 15 May 2016
- journal article
- research article
- Published by Hindawi Limited in Structural Control and Health Monitoring
- Vol. 24 (3) , e1878
Abstract
This study performs an experimental investigation of a novel, semi-active control strategy for effective vibration mitigation. The implemented approach comprises a combination of the linear quadratic regulator with a nonlinear observer, namely, the unscented Kalman filter, for the control of systems described by uncertainties. Indeed, numerical models of structural systems often result as inadequate because of inherent uncertainties, such as noise, modeling errors, unknown system properties, or influence of varying operational and environmental conditions. In tackling this issue, the unscented Kalman filter is herein employed for adaptive joint state and parameter estimation refining the accuracy of the model employed by the controller and resulting in enhanced vibration mitigation. A scaled five-story shear frame attached to a hydraulic cylinder comprises the tested structure, where actuation is provided by means of a rotational magnetorheological damper operating on the relative motion between the ground floor and the first floor plate. The experimentally obtained results demonstrate a good agreement with simulations and encourage further implementation of the proposed framework in field applications of structural control. Copyright © 2016 John Wiley & Sons, Ltd.Keywords
Funding Information
- Albert-Lück Foundation
This publication has 25 references indexed in Scilit:
- Semi-active control of a wind turbine via magnetorheological dampersJournal of Sound and Vibration, 2015
- Robust force tracking control scheme for MR dampersStructural Control and Health Monitoring, 2015
- A European Association for the Control of Structures joint perspective. Recent studies in civil structural control across EuropeStructural Control and Health Monitoring, 2014
- Semi-active adaptive control of seismically excited 20-story nonlinear buildingEngineering Structures, 2013
- Comparison of Control Laws for Vibration Suppression Based on Energy ConsumptionJournal of Intelligent Material Systems and Structures, 2011
- Real-time Hybrid Test on a Semi-actively Controlled Building Structure Equipped with Full-scale MR DampersJournal of Intelligent Material Systems and Structures, 2010
- Seismic-vibration mitigation of a nonlinear structural system with an ATMD through a fuzzy PID controllerNonlinear Dynamics, 2009
- Experimental validation of semi‐active resetable actuators in a ⅕th scale test structureEarthquake Engineering & Structural Dynamics, 2008
- State of the Art of Structural ControlJournal of Structural Engineering, 2003
- Passive Control Systems for Seismic Damage MitigationJournal of Structural Engineering, 1998