Spontaneous Resolution of Extensive Descemet Membrane Detachment Caused by Sodium Cyanide Injury to the Eye
Authors:
- Fei PanFPFei Pan
- Yu-Feng YaoYYYu-Feng Yao
- 1 November 2012
- journal article
- case report
- Published by Wolters Kluwer Health in Cornea
- Vol. 31 (11) , 1344-1347
Abstract
To describe the clinical course, ultrasonographic and confocal microscopic findings in a patient who developed a large Descemet membrane (DM) detachment that resolved spontaneously after ocular sodium cyanide injury. Case report. The patient presented with severe corneal stroma edema, a large detachment of DM, iritis, and anterior subcapsular lens opacity in the left eye caused by contact with 5% sodium cyanide. The ultrasound biomicroscopic and in vivo confocal microscopic examination exhibited the configuration of the DM detachment and extensive damage of corneal cells. Although no viable endothelial cells were observed with in vivo confocal microscopy, the DM spontaneously reattached 11 days after injury, coincident with increased intraocular pressure. However, persistent corneal edema and iris atrophy were observed 6 months after DM reattached. Sodium cyanide can cause severe injuries to the cornea and the anterior segment. Extensive DM detachment may resolve spontaneously despite the absence of viable endothelial cells.Keywords
This publication has 12 references indexed in Scilit:
- A Review of Acute Cyanide Poisoning With a Treatment UpdateCritical Care Nurse, 2011
- Descemet Membrane Detachment Caused by Hydrogen Peroxide InjuryCornea, 2004
- Descemet membrane detachment with hemorrhage after alkali burn to the corneaAmerican Journal of Ophthalmology, 2004
- Repair of late Descemet's membrane detachment with perfluoropropane gasJournal of Cataract & Refractive Surgery, 2003
- Descemet’s membrane detachment after cataract surgery: management and outcomeOphthalmology, 2002
- Descemet membrane detachment after sequential argon-neodymium:YAG laser peripheral iridotomyAmerican Journal of Ophthalmology, 2002
- Descemet Membrane Detachment After Nonpenetrating Filtering SurgeryJournal of Glaucoma, 2002
- Late spontaneous resolution of a massive detachment of Descemet's membrane after phacoemulsificationJournal of Cataract & Refractive Surgery, 2002
- Technique for repair of descemet membrane detachmentAmerican Journal of Ophthalmology, 1999
- Spontaneous Resolution of an Extensive Detachment of Descemet's Membrane Following PhacoemulsificationArchives of Ophthalmology (1950), 1994