Evaluation of combined heat and power (CHP) systems performance with dual power generation units for different building configurations
- 4 October 2012
- journal article
- research article
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 37 (12) , 1529-1538
Abstract
This paper evaluates the economic, energetic, and environmental feasibility of using two power generation units (PGUs) to operate a combined heat and power (CHP) system. Several benchmark buildings developed by the Department of Energy simulated using the weather data for Chicago, IL, are used to analyze the proposed configuration. This location has been selected because it usually provides favorable CHP system conditions in terms of cost and emission reduction. For the proposed configuration, one PGU is operated at base load to satisfy part of the electricity building requirements, whereas the other is used to satisfy the remaining electricity requirement operating following the electric load. The dual-PGU CHP configuration (D-CHP) is modeled for four different scenarios to determine the optimum operating range for the selected benchmark buildings. The dual-PGU scenario is compared with the reference building using conventional technology to determine the benefits of this proposed system in terms of operational cost, primary energy reduction, and carbon dioxide emissions. The D-CHP system results are also compared with a CHP system operating following the electric load (FEL) and base-loaded CHP system. For three of the selected buildings, the proposed D-CHP system provides comparable or greater savings in operating cost, primary energy consumption, and carbon dioxide emissions than the optimized conditions for base loading and FEL. In addition, the effect of operating the D-CHP system only during certain months of the year on the overall operational cost is also evaluated. Results indicate that not operating the D-CHP system for the months where the thermal load is too low is beneficial for the overall system performance. Copyright © 2012 John Wiley & Sons, Ltd.Keywords
This publication has 16 references indexed in Scilit:
- Evaluation of the potential emissions reductions from the use of CHP systems in different commercial buildingsBuilding and Environment, 2012
- Performance comparison of combined cooling heating and power system in different operation modesApplied Energy, 2011
- Analysis of combined cooling, heating, and power systems operating following the electric load and following the thermal load strategies with no electricity exportProceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy, 2011
- Modeling of a thermal energy storage system coupled with combined heat and power generation for the heating requirements of a University CampusApplied Thermal Engineering, 2010
- A review on energy, economical, and environmental benefits of the use of CHP systems for small commercial buildings for the North American climateInternational Journal of Energy Research, 2009
- Analysis and optimization of CCHP systems based on energy, economical, and environmental considerationsEnergy and Buildings, 2009
- Performance analysis of CCHP and CHP systems operating following the thermal and electric loadInternational Journal of Energy Research, 2009
- Efficiency analysis of a cogeneration and district energy systemApplied Thermal Engineering, 2005
- Mini- and micro-gas turbines for combined heat and powerApplied Thermal Engineering, 2002
- The energetic feasibility of CHP compared to the separate production of heat and powerApplied Thermal Engineering, 1998