Partial discharges monitoring in twisted pair fed with PWM inverter using non-intrusive sensors
Authors:
- 1 June 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 314-317
Abstract
This paper deals with partial discharge measurements in twisted pair fed by a PWM inverter. Measurements are carried out using antenna sensors. Both D-Dot sensor and self-made sensors are compared when it comes to detect partial discharge in a PWM environment. High-pass filter performance is tested as well with these sensors. Finally, a innovative noise suppression method is demonstrated using two identical antenna sensors. This method could be a useful and simple mean to improve signal to noise ratio before signal processing.Keywords
This publication has 9 references indexed in Scilit:
- Off-line and on-line pd measurements on induction motors fed by power electronic impulses2009
- Measuring partial discharges under pulsed voltage conditionsIEEE Transactions on Dielectrics and Electrical Insulation, 2008
- Development of a new off-line test procedure for low voltage rotating machines fed by adjustable speed drives (ASD)IEEE Transactions on Dielectrics and Electrical Insulation, 2003
- Advancements in partial discharge analysis to diagnose stator winding problems2002
- Transient voltage distribution in inverter fed motor windings: experimental study and modelingIEEE Transactions on Power Electronics, 2001
- Testing of low-voltage motor turn insulation intended for pulse-width modulated applicationsIEEE Transactions on Dielectrics and Electrical Insulation, 2000
- Electrical stresses applied tostator insulation in low-voltage induction motorsfed by PWM drivesIEE Proceedings - Electric Power Applications, 1997
- Existence of partial discharges in low-voltage induction machines supplied by PWM drivesIEEE Transactions on Dielectrics and Electrical Insulation, 1996
- Transient effects in application of PWM inverters to induction motorsIEEE Transactions on Industry Applications, 1992