Bedside ultrasound diagnosis of a malpositioned central venous catheter
Open Access
- 1 April 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine
- Vol. 97 (15) , e0501
Abstract
Central venous catheter (CVC) placement is commonly performed in intensive care unit. And CVC placement is associated with risks including CVC malposition, pneumothorax. Many of the previously reported cases are about catheter misplacement detected by bedside ultrasound, chest x-ray (CXR) and computed tomography. In this case, malposition was detected by bedside ultrasound incidentally particularly with no clinical manifestation. An 88-year-old male with severe diabetic peripheral neuropathy secondary to type 2 diabetes mellitus was admitted for further treatment. We cannulated a single-lumen CVC via the right subclavian vein, and the tip ended up in the internal jugular vein on the same side. With bedside ultrasound, we discovered the malposition though it was mistaken by aspiration of venous blood. Later, CXR revealed malposition of the tip once again. Since the patient was asymptomatic and the catheter was functioning normally, the catheter was used for the following 20 days without complications. Ultimately, we carefully performed the catheter removal. After the inserted catheter was removed, we attempted a new CVC through the left internal jugular vein. After the procedure, bedside ultrasound and CXR confirmed the correct position of CVC. Following successful replacement of the central catheter, no further complications were observed. Bedside ultrasound offers safety and effectiveness during insertion of CVC. It also exhibits promptness and accuracy compared to post-intervention radiological imaging.Keywords
This publication has 21 references indexed in Scilit:
- Pleural ultrasonography versus chest radiography for the diagnosis of pneumothorax: review of the literature and meta-analysisCritical Care, 2013
- An unseen danger: Frequency of posterior vessel wall penetration by needles during attempts to place internal jugular vein central catheters using ultrasound guidance*Critical Care Medicine, 2009
- Comparison of Routine Chest Radiograph Versus Clinician Judgment to Determine Adequate Central Line Placement in Critically Ill PatientsJournal of Trauma: Injury, Infection & Critical Care, 2007
- Ultrasound diagnosis of occult pneumothorax*Critical Care Medicine, 2005
- Preventing Complications of Central Venous CatheterizationThe New England journal of medicine, 2003
- Azygos Arch Cannulation by Central Venous CathetersJournal of Thoracic Imaging, 1997
- Ultrasound guidance for placement of central venous cathetersCritical Care Medicine, 1996
- Complications and Failures of Subclavian-Vein CatheterizationNew England Journal of Medicine, 1994
- Cardiac tamponade from misplaced central venous line in pericardiophrenic veinArchives of internal medicine (1960), 1988
- Septic and Technical Complications of Central Venous CatheterizationAnnals of Surgery, 1985