Study of a Compact HPM System With a Reflex Triode and a Marx Generator
Authors:
- 16 October 2006
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 34 (5) , 1796-1805
Abstract
To study the performance of compact systems for microwave generation, a series of experiments have been performed with a microwave source powered directly by a Marx generator. The system consists of a 20-stage 400-kV/400-J Marx generator, a powerful 40-kV charger, a reflex triode, and a vircator-type microwave source. Different parametric studies were performed such as variation of the anode-cathode distances and the emitting area of the cathode. The results have been analyzed and compared to an equivalent electric circuit model of the system. The experiments, generating microwave frequencies between 3 and 5 GHz, can be fairly accurately reproduced by the model both in terms of discharge currents and microwave frequenciesKeywords
This publication has 6 references indexed in Scilit:
- Comparison Between Experimental and Numerical Studies of a Reflex Triode2005
- Microwave Frequency Determination Mechanisms in a Coaxial VircatorIEEE Transactions on Plasma Science, 2004
- Single shot overstressing of high voltage capacitors for compact Arkadiev-Marx generator2004
- Experimental and Simulation Studies of New Configuration of Virtual Cathode OscillatorIEEE Transactions on Plasma Science, 2004
- High-Power Microwave Sources and Technologies2001
- A Practical Guide to Wavelet AnalysisBulletin of the American Meteorological Society, 1998