Percutaneous closure of perimembranous ventricular septal defect using patent ductus arteriosus occluders
Open Access
- 15 November 2018
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (11) , e0206535
Abstract
To assess the safety and efficacy of percutaneous closure of perimembranous ventricular septal defect (PmVSD) using patent ductus arteriosus (PDA) occluders. Widespread use of conventional PmVSD closure devices has been limited by unacceptable high rate of complete heart block (CHB). The elegant design of PDA occluders is supposed to ease implantation, increase closure rate and minimize damage to adjacent structures. Thus, PDA occluders may reduce complications, especially the CHB, and offer a good alternative for PmVSD closure. From September 2008 to October 2015, patients who underwent attempted percutaneous VSD closure using PDA occluders were included in the study. Patient demographics, echocardiography measurements, procedure details and follow-up data until October 2017 were collected. In total, 321 patients with a mean age of 15.5±12.6 years and mean a weight of 33.3±20.5 kg were included in this study. The mean defect size was 4.8±2.1 mm. Implantation was successful in 307 (95.6%) patients. The median follow-up time was 63 months (24 to 108 months). The closure rates were 89.5%, 91.5%, and 99.3% after the procedure 24 hours, 6 months and 2 years, respectively. Major complications occurred in 5 (1.7%) patients during the procedure and follow-up, including persistent CHB in 2 (0.7%) patients and device embolization in 3 (1.0%) patients. No death, disability, or other major complication was detected. Percutaneous closure of PmVSD using PDA occluders is feasible, safe and efficacious in selected patients.Keywords
This publication has 50 references indexed in Scilit:
- No escape from a VSD device? Complete heart block and cardiac arrest associated with a ventricular septal defect occluder devicePediatric Anesthesia, 2011
- The results of transcatheter closure of VSD using amplatzer® device and nit occlud® Lê coilCatheterization and Cardiovascular Interventions, 2011
- Transcatheter device closure of perimembranous ventricular septal defects: mid-term outcomesEuropean Heart Journal, 2010
- Early and delayed atrioventricular conduction block after routine surgery for congenital heart diseaseThe Journal of Thoracic and Cardiovascular Surgery, 2010
- Transcatheter closure of perimembranous ventricular septal defect: Figure 1Heart, 2007
- Transcatheter closure of congenital ventricular septal defects: results of the European RegistryEuropean Heart Journal, 2007
- Ventricular Septal DefectsCirculation, 2006
- Transcatheter closure of perimembranous ventricular septal defect: is the risk of heart block too high a price?Heart, 2006
- Transcatheter closure of perimembranous ventricular septal defects using amplatzer asymmetric ventricular septal defect occluder: Preliminary experience with 18‐month follow upCatheterization and Cardiovascular Interventions, 2006
- Outcome of patients after surgical closure of ventricular septal defect at young age: longitudinal follow-up of 22?34 yearsEuropean Heart Journal, 2004