Abstract
This study aimed to evaluate the feasibility and utility of using motorized pullback of the pressure guidewire to provide a graphic assessment and prediction of the benefits of coronary intervention. Fractional flow reserve (FFR) measurements were performed with motorized pullback imaging in 20 patients who underwent successful percutaneous coronary intervention (PCI) of the left anterior descending artery. Physiological lesion length (PLL) was calculated using frame counts to determine stent length. FFR area was calculated by integrating the FFR values recorded during pullback tracing (FFRarea). The percentage increase in FFR area (%FFRarea) was defined as the ratio of the difference between the pre- and post-intervention FFRarea to the total frame count. The average FFR values were enhanced following PCI, from 0.64 to 0.82, and the median value of the difference between pre- and post-interventional FFR values (D-FFR) and %FFRarea were 0.13 and 10.6%, respectively. The %FFRarea demonstrated a significant positive correlation with D-FFR (R 2, 0.61; p < 0.01). PLL tended to be longer and the %FFRarea was smaller in lesions with a gradual pressure-drop pattern than those with an abrupt pressure-drop pattern (35.37 vs. 20.40 mm, p = 0.07; 5.78 vs. 16.21%, p < 0.05, respectively). Motorized pullback tracing was able to identify the extent and location of stenosis and help in appropriate stent implantation, in addition to visualizing and quantifying the improvement in FFR following PCI.Keywords
This publication has 28 references indexed in Scilit:
- Coronary pressure measurement identifies patients with diffuse coronary artery disease who benefit from coronary revascularizationCoronary Artery Disease, 2011
- Baseline Fractional Flow Reserve and Stent Diameter Predict Optimal Post-Stent Fractional Flow Reserve and Major Adverse Cardiac Events After Bare-Metal Stent DeploymentJACC: Cardiovascular Interventions, 2009
- Influence of a Pressure Gradient Distal to Implanted Bare-Metal Stent on In-Stent Restenosis After Percutaneous Coronary InterventionCirculation, 2007
- Percutaneous Coronary Intervention of Functionally Nonsignificant StenosisJACC, 2007
- Fractional flow reserve for the prediction of cardiac events after coronary stent implantation: results of a multivariate analysisHeart, 2005
- Fractional flow reserve and complex coronary pathologic conditionsEuropean Heart Journal, 2004
- Comparison of the Short-Term Survival Benefit Associated With Revascularization Compared With Medical Therapy in Patients With No Prior Coronary Artery Disease Undergoing Stress Myocardial Perfusion Single Photon Emission Computed TomographyCirculation, 2003
- Coronary Pressure Measurement After Stenting Predicts Adverse Events at Follow-UpCirculation, 2002
- Measurement of Fractional Flow Reserve to Assess the Functional Severity of Coronary-Artery StenosesNew England Journal of Medicine, 1996
- Scintigraphic quantification of myocardial ischemia: a new approach.Circulation, 1983