Accuracy of volumetric measurement of simulated root resorption lacunas based on cone beam computed tomography
Authors:
- 19 February 2013
- journal article
- research article
- Published by Wiley in Orthodontics & Craniofacial Research
- Vol. 16 (3) , 169-176
Abstract
Structured Objectives: To evaluate the accuracy of volumetric measurement of simulated root resorption cavities based on cone beam computed tomography (CBCT), in comparison with that of Micro‐computed tomography (Micro‐CT) which served as the reference.Setting and Sample Population: The State Key Laboratory of Oral Diseases at Sichuan University.Material and Methods: Thirty‐two bovine teeth were included for standardized CBCT scanning and Micro‐CT scanning before and after the simulation of different degrees of root resorption. The teeth were divided into three groups according to the depths of the root resorption cavity (group 1: 0.15, 0.2, 0.3 mm; group 2: 0.6, 1.0 mm; group 3: 1.5, 2.0, 3.0 mm). Each depth included four specimens. Differences in tooth volume before and after simulated root resorption were then calculated from CBCT and Micro‐CT scans, respectively. The overall between‐method agreement of the measurements was evaluated using the concordance correlation coefficient (CCC).Results: For the first group, the average volume of resorption cavity was 1.07 mm3, and the between‐method agreement of measurement for the volume changes was low (CCC = 0.098). For the second and third groups, the average volumes of resorption cavities were 3.47 and 6.73 mm3 respectively, and the between‐method agreements were good (CCC = 0.828 and 0.895, respectively).Conclusions: The accuracy of 3‐D quantitative volumetric measurement of simulated root resorption based on CBCT was fairly good in detecting simulated resorption cavities larger than 3.47 mm3, while it was not sufficient for measuring resorption cavities smaller than 1.07 mm3. This method could be applied in future studies of root resorption although further studies are required to improve its accuracy.Keywords
This publication has 21 references indexed in Scilit:
- Accuracy of volumetric measurement of teeth in vivo based on cone beam computer tomographyOrthodontics & Craniofacial Research, 2011
- Accuracy of 3D Reconstructions Based on Cone Beam Computed TomographyJournal of Dental Research, 2010
- In-vitro comparison of 2 cone-beam computed tomography systems and panoramic imaging for detecting simulated canine impaction-induced external root resorption in maxillary lateral incisorsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2009
- Detection of apical root resorption after orthodontic treatment by using panoramic radiography and cone-beam computed tomography of super-high resolutionAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2009
- Diagnostic ability of computed tomography to evaluate external root resorptionin vitroDentomaxillofacial Radiology, 2007
- Flaws in root resorption assessment algorithms: Role of tooth shapeAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2006
- Physical properties of root cementum: Part 8. Volumetric analysis of root resorption craters after application of controlled intrusive light and heavy orthodontic forces: A microcomputed tomography scan studyAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2006
- Conventional and digital radiographic methods in the detection of simulated external root resorptions: a comparative studyDentomaxillofacial Radiology, 2004
- External root resorption: An experimental radiographic evaluationOral Surgery, Oral Medicine, Oral Pathology, 1989
- Radiographic assessment of simulated root resorption cavitiesDental Traumatology, 1987