Variation in the shape of pulsed arterial spin labeling kinetic curves across the healthy human brain and its implications for CBF quantification
Open Access
- 8 January 2009
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 61 (3) , 686-695
Abstract
Arterial spin labeling (ASL) uses proximally inverted blood water spins as an endogenous contrast agent to measure blood perfusion in tissue. In this work pulsed ASL was used to measure the kinetic curves of cerebral blood flow (CBF) across eight anatomically based regions of interest (ROIs) in five normal healthy subjects. CBF estimates based on these data were compared when obtained using a single inversion time versus fitting a kinetic model to all 10 measured inversion times. CBF estimates were also compared when fitting to the 10 inversion time data using a standard two-parameter approach (CBF and bolus arrival time) or a more recently proposed three-parameter model (CBF, bolus arrival time, and arrival time dispersion). Variations in the shape of the kinetic curve were found across the brain that were consistent across subjects. The arrival time in the occipital ROI was found to be long enough to lead to underestimation of the CBF when using a single inversion time of 1.5 s. In four out of the eight ROIs there was significant underestimation of CBF using the standard two-parameter model compared to the three-parameter approach. These results have important implications for the development of a robust, quantitative ASL protocol. Magn Reson Med, 2009.Keywords
This publication has 21 references indexed in Scilit:
- T1, T2 relaxation and magnetization transfer in tissue at 3TMagnetic Resonance in Medicine, 2005
- Determining the longitudinal relaxation time (T1) of blood at 3.0 TeslaMagnetic Resonance in Medicine, 2004
- Two analytical solutions for a model of pulsed arterial spin labeling with randomized blood arrival timesJournal of Magnetic Resonance, 2004
- Effects of hematocrit and oxygen saturation level on blood spin‐lattice relaxationMagnetic Resonance in Medicine, 2003
- QUIPSS II with thin-slice TI1 periodic saturation: A method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labelingMagnetic Resonance in Medicine, 1999
- Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniquesMagnetic Resonance in Medicine, 1997
- Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopyMagnetic Resonance in Medicine, 1996
- Magnetic resonance imaging of perfusion using spin inversion of arterial water.Proceedings of the National Academy of Sciences, 1992
- Perfusion imagingMagnetic Resonance in Medicine, 1992
- THE NITROUS OXIDE METHOD FOR THE QUANTITATIVE DETERMINATION OF CEREBRAL BLOOD FLOW IN MAN: THEORY, PROCEDURE AND NORMAL VALUES 1Journal of Clinical Investigation, 1948