Vision-Guided Autonomous Robotic Electrical Bio-Impedance Scanning System for Abnormal Tissue Detection
- 21 July 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 3 (4) , 866-877
Abstract
In cancer surgery, the correct localization of cancerous tissue is critical for the success of the surgery. Specifically, the surgical goal is to remove the malignant tissue completely while preserving the maximum amount of healthy tissue. Unfortunately, limited technologies are available for intra-operative assessment of tumor margin in Robotic Minimally Invasive Surgery (RMIS). This work presents a vision-based autonomous robotic scanning system for abnormal tissue detection. A stereo vision system, including dense 3D surface reconstruction and tissue tracking, is used to control the scanning motion to compensate for tissue motion and deformation. A high level control strategy allows to control a robot arm to scan autonomously the tissue by means of a monopolar forceps measuring the Electric Bio-Impedance (EBI) of the tissue. The acquired information is used for discriminating cancerous from healthy tissue in real-time, and this information is presented as an impedance map overlaid on the endoscopic video using Augmented Reality (AR). The proposed system performance is evaluated on ex-vivo animal tissues, through experiments simulating the identification and localization of hepatic cancer for resection surgery. Quantitative results show that the system is able to autonomously scan the area of interest and provide a tissue characterization with an accuracy over 82%.Keywords
This publication has 33 references indexed in Scilit:
- Laparoscopic versus open liver resection for hepatocellular carcinoma: Case-matched study with propensity score matchingJournal of Hepatology, 2015
- Determinants and effects of positive surgical margins after prostatectomy on prostate cancer mortality: a population-based studyBMC Urology, 2014
- Drilling Electrode for Real-Time Measurement of Electrical Impedance in Bone TissuesAnnals of Biomedical Engineering, 2013
- Inverse analysis and robustness evaluation for biological structure behaviour in FE simulation: application to the liverComputer Methods in Biomechanics and Biomedical Engineering, 2012
- Robot-assisted laparoscopic hemi-hepatectomy: Technique and surgical outcomesInternational Journal of Surgery, 2012
- Electrical impedance characterization of normal and cancerous human hepatic tissuePhysiological Measurement, 2010
- Robot-assisted Tactile Sensing for Minimally Invasive Tumor LocalizationThe International Journal of Robotics Research, 2009
- Impedance-based tissue discrimination for needle guidancePhysiological Measurement, 2009
- Biomechanical Properties of Abdominal Organs In Vivo and Postmortem Under Compression LoadsJournal of Biomechanical Engineering, 2008
- An Evaluation of the Decreasing Incidence of Positive Surgical Margins in a Large Retropubic Prostatectomy SeriesJournal of Urology, 2004