Design and Fabrication of a Miniaturized Convex Array for Combined Ultrasound and Photoacoustic Imaging of the Prostate
- 10 August 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (11) , 2086-2096
Abstract
Although transrectal ultrasound (TRUS) imaging is widely used for screening and diagnosing prostate cancer, prostate cancer is often not found on TRUS images, depending on its stage, size, and location. Additionally, due to the weak echo signal and the low contrast of TRUS images, it is difficult to diagnose early-stage prostate cancers and distinguish malignant tumors from benign prostatic hyperplasia. For this reason, TRUS image-guided biopsy is mandatory to confirm the malignancy of the suspicious tumor, but the diagnostic accuracy of initial biopsy is only 20 to 30%, so that the patients inevitably undergo repeated biopsies. Transrectal ultrasound-photoacoustic (TRUS-PA) imaging is one way to resolve those problems. However, the development of a TRUS-PA probe, in which an ultrasound array transducer and optical fibers are integrated, is demanding because the overall size of the probe should be as small as possible for the convenience of the patients, while providing the desired performances. Here, we report a recently developed TRUS-PA probe. The core element of the TRUS-PA is a miniaturized 128-element, 7-MHz convex array transducer of which size in the lateral and elevational directions are 11.4 and 5 mm, respectively. A new concept of flexible printed circuit board (FPCB) was also developed to limit the size of the TRUS-PA probe to less than 15 mm. From the performance evaluation, it was found that the developed array with a field-of-view of 134° has a center frequency of 6.75 MHz, a -6 dB fractional bandwidth of 66%, and a crosstalk of less than -45 dB. In the tissue mimicking phantom test and ex vivo experiments, the miniaturized convex array proved to be capable of providing combined US and PA images with acceptable imaging quality in spite of its small size.Keywords
Funding Information
- Korea Evaluation Institute of Industrial Technology (10060071)
This publication has 55 references indexed in Scilit:
- MRI–ultrasound fusion for guidance of targeted prostate biopsyCurrent Opinion in Urology, 2013
- Are Hypoechoic Lesions on Transrectal Ultrasonography a Marker for Clinically Significant Prostate Cancer?Korean Journal of Urology, 2013
- A 5-MHz Cylindrical Dual-Layer Transducer Array for 3-D Transrectal Ultrasound ImagingUltrasonic Imaging, 2012
- Effect of Obesity on Prostate-Specific Antigen, Prostate Volume, and International Prostate Symptom Score in Patients with Benign Prostatic HyperplasiaKorean Journal of Urology, 2011
- Deeply penetrating in vivo photoacoustic imaging using a clinical ultrasound array systemBiomedical Optics Express, 2010
- Sentinel Lymph Nodes in the Rat: Noninvasive Photoacoustic and US Imaging with a Clinical US SystemRadiology, 2010
- Handheld array-based photoacoustic probe for guiding needle biopsy of sentinel lymph nodesJournal of Biomedical Optics, 2010
- Optoacoustic imaging of the prostate: development toward image-guided biopsyJournal of Biomedical Optics, 2010
- Ultrasound of the prostateCancer Imaging, 2010
- Population-Based Case-Control Study of PSA and DRE Screening on Prostate Cancer MortalityUrology, 2007