Improved mediolateral load distribution without adverse laxity pattern in robot-assisted knee arthroplasty compared to a standard manual measured resection technique
Authors:
Open Access
- 27 July 2019
- journal article
- research article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 28 (9) , 2835-2845
Abstract
Purpose Robot-assisted total knee arthroplasty (rTKA) remains in its infancy, is expensive but offers the promise of improved kinematic performance through precise bone cuts, with minimal soft tissue disruption, based on pre-resection soft tissue behaviour. This cadaveric study examined load transfer, soft tissue performance and radiographic indices for conventional (sTKA) versus rTKA. The null hypothesis was there would be no difference between the two modes of implantation. Methods Whole (ten) cadaveric limbs were randomised to receive either robotic (rTKA, N = 5) or conventional measured resection (sTKA, N = 5) knee arthroplasty. Laxity patterns were established using validated fixed sensors (Verasense) with manual maximum displacement for six degrees of freedom. Tibiofemoral load and contact points were determined dynamically using remote sensor technology for medial and lateral compartments through a functional arc of motion (0–110 degrees of motion). Final component position was assessed using pre- and post-implantation CT. Results No significant intergroup differences for laxity were found (n.s.). The rTKA group exhibited consistently balanced mediolateral load throughout the full arc with significantly reduced overall total load across the joint (for distinct points of measurement, p < 0.05). Despite using flexion–extension and mediolateral gap balancing with measured resection, the sTKA group failed to achieve balance in at least three points of the flexion arc. Post-operative CT confirmed satisfactory component alignment with no significant differences for positioning between the two groups. Conclusion This work found improved load sharing for rTKA when compared to conventional surgery for same donor knees. Laxity and CT determined final component positioning was not significantly different. The work supports the contention that robot-assisted TKA delivers improved tibiofemoral load sharing in time zero studies under defined conditions but such offers the promise of improved clinical performance and reduced implant wear.Keywords
This publication has 44 references indexed in Scilit:
- Does A Kinematically Aligned Total Knee Arthroplasty Restore Function Without Failure Regardless of Alignment Category?Clinical Orthopaedics and Related Research, 2013
- The kinematics and stability of single‐radius versus multi‐radius femoral components related to Mid‐range instability after TKAJournal of Orthopaedic Research, 2012
- Does computer‐assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta‐analysis of randomized controlled trials?Knee Surgery, Sports Traumatology, Arthroscopy, 2011
- The position and orientation of total knee replacement componentsThe Journal of Bone and Joint Surgery. British volume, 2011
- Evaluation of tibial rotational alignment in total knee arthroplasty: a cadaver studyKnee Surgery, Sports Traumatology, Arthroscopy, 2010
- Three‐dimensional patellar motion at the natural knee during passive flexion/extension. An in vitro studyJournal of Orthopaedic Research, 2009
- Factors Affecting Flexion after Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2007
- Comparison of Robotic-Assisted and Conventional Manual Implantation of a Primary Total Knee ArthroplastyThe Journal of Arthroplasty, 2007
- The role of pain and function in determining patient satisfaction after total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2007
- Computer navigation versus conventional total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2007