Circumferential lesion formation around the pulmonary veins in the left atrium with focused ultrasound using a 2D-array endoesophageal device: a numerical study
Authors:
- Samuel PichardoSPSamuel Pichardo
- Kullervo HynynenKHKullervo Hynynen
Open Access
- 30 July 2007
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (16) , 4923-4942
Abstract
Atrial fibrillation (AF) is the most frequently sustained cardiac arrhythmia affecting humans. The electrical isolation by ablation of the pulmonary veins (PVs) in the left atrium (LA) of the heart has been proven as an effective cure of AF. The ablation consists mainly in the formation of a localized circumferential thermal coagulation of the cardiac tissue surrounding the PVs. In the present numerical study, the feasibility of producing the required circumferential lesion with an endoesophageal ultrasound probe is investigated. The probe operates at 1 MHz and consists of a 2D array with enough elements (114 × 20) to steer the acoustic field electronically in a volume comparable to the LA. Realistic anatomical conditions of the thorax were considered from the segmentation of histological images of the thorax. The cardiac muscle and the blood-filled cavities in the heart were identified and considered in the sound propagation and thermal models. The influence of different conditions of the thermal sinking in the LA chamber was also studied. The circumferential ablation of the PVs was achieved by the sum of individual lesions induced with the proposed device. Different scenarios of lesion formation were considered where ultrasound exposures (1, 2, 5 and 10 s) were combined with maximal peak temperatures (60, 70 and 80 °C). The results of this numerical study allowed identifying the limits and best conditions for controlled lesion formation in the LA using the proposed device. A controlled situation for the lesion formation surrounding the PVs was obtained when the targets were located within a distance from the device in the range of 26 ± 7 mm. When combined with a maximal temperature of 70 °C and an exposure time between 5 and 10 s, this distance ensured preservation of the esophageal structures, controlled lesion formation and delivery of an acoustic intensity at the transducer surface that is compatible with existing materials. With a peak temperature of 70 °C, the device and setup presented here induced highly localized lesions with a lesion volume varying from 10 ± 4 to 18 ± 7 mm3 for an ultrasound exposure between 5 and 10 s, respectively, while the intensity varied from 26 ± 7 to 20 ± 6 W cm−2.Keywords
This publication has 28 references indexed in Scilit:
- Mechanical Esophageal Deflection During Ablation of Atrial FibrillationPacing and Clinical Electrophysiology, 2006
- Movement of the Esophagus During Left Atrial Catheter Ablation for Atrial FibrillationJACC, 2005
- Techniques for Curative Treatment of Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2004
- FEM analysis of predicting electrode-myocardium contact from RF cardiac catheter ablation system impedanceIEEE Transactions on Biomedical Engineering, 2002
- Propagation speed of sound assessment in the layers of the guinea-pig esophagus in vitro by means of acoustic microscopyUltrasonics, 2001
- Dependence of ultrasonic attenuation and absorption in dog soft tissues on temperature and thermal doseThe Journal of the Acoustical Society of America, 1997
- Evaluation of accuracy of a theoretical model for predicting the necrosed tissue volume during focused ultrasound surgeryIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1995
- The effects of curved tissue layers on the power deposition patterns of therapeutic ultrasound beamsMedical Physics, 1994
- Effects of pulsed ultrasound on the mouse neonate: Hind limb paralysis and lung hemorrhageUltrasound in Medicine & Biology, 1994
- The feasibility of using electrically focused ultrasound arrays to induce deep hyperthermia via body cavitiesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1991