Comparative measurement of collagen bundle orientation by Fourier analysis and semiquantitative evaluation: reliability and agreement in Masson's trichrome, Picrosirius red and confocal microscopy techniques
- 20 March 2017
- journal article
- research article
- Published by Wiley in Journal of Microscopy
- Vol. 267 (2) , 130-142
Abstract
Summary: Measurement of collagen bundle orientation in histopathological samples is a widely used and useful technique in many research and clinical scenarios. Fourier analysis is the preferred method for performing this measurement, but the most appropriate staining and microscopy technique remains unclear. Some authors advocate the use of Haematoxylin‐Eosin (H&E) and confocal microscopy, but there are no studies comparing this technique with other classical collagen stainings. In our study, 46 human skin samples were collected, processed for histological analysis and stained with Masson's trichrome, Picrosirius red and H&E. Five microphotographs of the reticular dermis were taken with a 200× magnification with light microscopy, polarized microscopy and confocal microscopy, respectively. Two independent observers measured collagen bundle orientation with semiautomated Fourier analysis with the Image‐Pro Plus 7.0 software and three independent observers performed a semiquantitative evaluation of the same parameter. The average orientation for each case was calculated with the values of the five pictures. We analyzed the interrater reliability, the consistency between Fourier analysis and average semiquantitative evaluation and the consistency between measurements in Masson's trichrome, Picrosirius red and H&E‐confocal. Statistical analysis for reliability and agreement was performed with the SPSS 22.0 software and consisted of intraclass correlation coefficient (ICC), Bland‐Altman plots and limits of agreement and coefficient of variation. Interrater reliability was almost perfect (ICC > 0.8) with all three histological and microscopy techniques and always superior in Fourier analysis than in average semiquantitative evaluation. Measurements were consistent between Fourier analysis by one observer and average semiquantitative evaluation by three observers, with an almost perfect agreement with Masson's trichrome and Picrosirius red techniques (ICC > 0.8) and a strong agreement with H&E‐confocal (0.7 < ICC < 0.8). Comparison of measurements between the three techniques for the same observer showed an almost perfect agreement (ICC > 0.8), better with Fourier analysis than with semiquantitative evaluation (single and average). These results in nonpathological skin samples were also confirmed in a preliminary analysis in eight scleroderma skin samples. Our results show that Masson's trichrome and Picrosirius red are consistent with H&E‐confocal for measuring collagen bundle orientation in histological samples and could thus be used indistinctly for this purpose. Fourier analysis is superior to average semiquantitative evaluation and should keep being used as the preferred method.Keywords
This publication has 42 references indexed in Scilit:
- Comparison of Histochemical Staining Methods and Correlation with Transient Elastography in Acute HepatitisPathobiology, 2015
- Three‐dimensional visualization of dermal skin structure using confocal laser scanning microscopyJournal of Microscopy, 2013
- Connective and mesenchymal tissues with their stains2013
- Quantitative assessment of forward and backward second harmonic three dimensional images of collagen Type I matrix remodeling in a stimulated cellular environmentJournal of Structural Biology, 2012
- Quantifying collagen structure in breast biopsies using second-harmonic generation imagingBiomedical Optics Express, 2012
- Imaging and 3D morphological analysis of collagen fibrilsJournal of Microscopy, 2012
- A Novel Histochemical Method for a Simultaneous Staining of Melanin and Collagen FibersJournal of Histochemistry & Cytochemistry, 2011
- The framework of pathology: good laboratory practice by quantitative and molecular methodsThe Journal of Pathology, 2002
- Reliability: What is it, and how is it measured?Physiotherapy, 2000
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986