Synthesized 7T MPRAGE From 3T MPRAGE Using Generative Adversarial Network and Validation in Clinical Brain Imaging: A Feasibility Study
Authors:
- 9 August 2023
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 59 (5) , 1620-1629
Abstract
Background: Ultra‐high field 7T MRI can provide excellent tissue contrast and anatomical details, but is often cost prohibitive, and is not widely accessible in clinical practice.Purpose: To generate synthetic 7T images from widely acquired 3T images with deep learning and to evaluate the feasibility of this approach for brain imaging.Study Type: Prospective.Population: 33 healthy volunteers and 89 patients with brain diseases, divided into training, and evaluation datasets in the ratio 4:1.Sequence and Field Strength: T1‐weighted nonenhanced or contrast‐enhanced magnetization‐prepared rapid acquisition gradient‐echo sequence at both 3T and 7T.Assessment: A generative adversarial network (SynGAN) was developed to produce synthetic 7T images from 3T images as input. SynGAN training and evaluation were performed separately for nonenhanced and contrast‐enhanced paired acquisitions. Qualitative image quality of acquired 3T and 7T images and of synthesized 7T images was evaluated by three radiologists in terms of overall image quality, artifacts, sharpness, contrast, and visualization of vessel using 5‐point Likert scales.Statistical Tests: Wilcoxon signed rank tests to compare synthetic 7T images with acquired 7T and 3T images and intraclass correlation coefficients to evaluate interobserver variability. P < 0.05 was considered significant.Results: Of the 122 paired 3T and 7T MRI scans, 66 were acquired without contrast agent and 56 with contrast agent. The average time to generate synthetic images was ~11.4 msec per slice (2.95 sec per participant). The synthetic 7T images achieved significantly improved tissue contrast and sharpness in comparison to 3T images in both nonenhanced and contrast‐enhanced subgroups. Meanwhile, there was no significant difference between acquired 7T and synthetic 7T images in terms of all the evaluation criteria for both nonenhanced and contrast‐enhanced subgroups (P ≥ 0.180).Data Conclusion: The deep learning model has potential to generate synthetic 7T images with similar image quality to acquired 7T images.Level of Evidence: 2Technical Efficacy: Stage 1Keywords
Funding Information
- National Natural Science Foundation of China (81825012, 82151309, 82202133)
This publication has 31 references indexed in Scilit:
- Key clinical benefits of neuroimaging at 7 TNeuroImage, 2018
- U-Net: Convolutional Networks for Biomedical Image Segmentation2015
- Ultra-High-Field MR NeuroimagingAmerican Journal of Neuroradiology, 2014
- Brain tumours at 7T MRI compared to 3T—contrast effect after half and full standard contrast agent dose: initial resultsEuropean Radiology, 2014
- Dielectric pads and low‐ adiabatic pulses: Complementary techniques to optimize structural T1w whole‐brain MP2RAGE scans at 7 teslaJournal of Magnetic Resonance Imaging, 2013
- 7 Tesla MPRAGE Imaging of the Intracranial Arterial VasculatureAcademic Radiology, 2013
- Robust Brain Extraction Across Datasets and Comparison With Publicly Available MethodsIEEE Transactions on Medical Imaging, 2011
- N4ITK: Improved N3 Bias CorrectionIEEE Transactions on Medical Imaging, 2010
- Image quality assessment: from error visibility to structural similarityIEEE Transactions on Image Processing, 2004
- Improved Optimization for the Robust and Accurate Linear Registration and Motion Correction of Brain ImagesNeuroImage, 2002