Is the high-performance thermoplastic polyetheretherketone indicated as a clasp material for removable dental prostheses?
Open Access
- 7 October 2020
- journal article
- research article
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 25 (5) , 2859-2866
Abstract
Objectives: To investigate the retention force of polyetheretherketone (PEEK) removable dental prosthesis clasps in comparison with a cobalt-chrome-molybdenum control group after storage in artificial saliva. Materials and Methods: Clasps were milled (Dentokeep (PEEKmilled1), NT digital implant technology; breCAM BioHPP Blank (PEEKmilled2), bredent), pressed (BioHPP Granulat for 2 press (PEEKpressed), bredent), or cast (remanium GM 800+ (cobalt-chrome-molybdenum), Dentaurum); N = 60, n = 15/subgroup. Retention force was examined 50 times/specimen in a pull-off test using the universal testing machine (Zwick 1445), where pull-off force was applied with a crosshead speed of 5 mm/minute until the maximum force dropped by 10%, at different aging levels: (1) initial, after storage in artificial saliva for (2) 90 and (3) 180 days. Statistical analysis was performed using one-way ANOVA followed by post hoc Scheffé-test and mixed models (p < 0.05). Results: Cobalt-chrome-molybdenum presented the highest retention force. No differences were observed between polyetheretherketone materials. Cobalt-chrome-molybdenum showed a significant decrease of its values after artificial aging, while polyetheretherketone materials presented similar results over the course of aging. Regarding a repetitive insertion and removal, even though PEEKmilled2 and cobalt-chrome-molybdenum showed an initial increase, ultimately, a decrease in retention force was observed for all tested groups. Conclusions: Although the control group showed significantly higher results, the retention force of polyetheretherketone materials indicate a potential clinical application. Neither the manufacturing process nor artificial aging showed an impact on the retention force of polyetheretherketone clasps. Clinical relevance: Mechanical properties of novel removable dental prosthesis clasp materials devised to meet the growing esthetic demands of patients need to be investigated to ensure a successful long-term clinical application.Keywords
Funding Information
- Universitätsklinik München
This publication has 44 references indexed in Scilit:
- Investigation of Mechanical Properties of Modern Dental Composites After Artificial Aging for One YearOperative Dentistry, 2010
- PEEK biomaterials in trauma, orthopedic, and spinal implantsBiomaterials, 2007
- Polyetheretherketone as a biomaterial for spinal applicationsBiomaterials, 2006
- An in vitro comparison of retentive force and deformation of acetal resin and cobalt-chromium claspsThe Journal of Prosthetic Dentistry, 2005
- Deflection fatigue of Ti-6Al-7Nb, Co-Cr, and gold alloy cast claspsThe Journal of Prosthetic Dentistry, 2005
- Analysis of stiffness and stress in I‐bar claspsJournal of Oral Rehabilitation, 2001
- Clasp designBritish Dental Journal, 2001
- Dimensional measurement and finite element analysis of I-bar clasps in clinical useJournal of Oral Rehabilitation, 2000
- A laboratory examination of the behaviour of cast cobalt‐chromium claspsJournal of Oral Rehabilitation, 1990
- Corrosion of Gold and Amalgam Placed in Contact with Each otherJournal of Dental Research, 1963