Mechanical Support in Early Cardiogenic Shock: What Is the Role of Intra-aortic Balloon Counterpulsation?
Authors:
Open Access
- 1 September 2020
- journal article
- research article
- Published by Springer Nature in Current Heart Failure Reports
- Vol. 17 (5) , 247-260
Abstract
Purpose of Review: We aim to summarize recent insights and provide an up-to-date overview on the role of intra-aortic balloon pump (IABP) counterpulsation in cardiogenic shock (CS).Recent Findings: In the largest randomized controlled trial (RCT) of patients with CS after acute myocardial infarction (AMICS), IABP did not lower mortality. However, recent data suggest a role for IABP in patients who have persistent ischemia after revascularization. Moreover, in the growing population of CS not caused by acute coronary syndrome (ACS), multiple retrospective studies and one small RCT report on significant hemodynamic improvement following (early) initiation of IABP support, which allowed bridging of most patients to recovery or definitive therapies like heart transplant or a left ventricular assist device (LVAD).Summary: Routine use of IABP in patients with AMICS is not recommended, but many patients with CS either from ischemic or non-ischemic cause may benefit from IABP at least for hemodynamic improvement in the short term. There is a need for a larger RCT regarding the role of IABP in selected patients with ACS, as well as in patients with non-ACS CS.Keywords
Funding Information
- University Medical Center Rotterdam
This publication has 68 references indexed in Scilit:
- A Prospective, Randomized Clinical Trial of Hemodynamic Support With Impella 2.5 Versus Intra-Aortic Balloon Pump in Patients Undergoing High-Risk Percutaneous Coronary InterventionCirculation, 2012
- Percutaneous cardiac support devices for cardiogenic shock: current indications and recommendationsHeart, 2012
- Benefits of ambulatory axillary intra-aortic balloon pump for circulatory support as bridge to heart transplantThe Journal of Thoracic and Cardiovascular Surgery, 2012
- Hemodynamic Effects of Intra-aortic Balloon Counterpulsation in Patients With Acute Myocardial Infarction Complicated by Cardiogenic ShockShock, 2012
- Subclavian Artery Access for Ambulatory Balloon Pump InsertionThe Annals of Thoracic Surgery, 2010
- A Randomized Clinical Trial to Evaluate the Safety and Efficacy of a Percutaneous Left Ventricular Assist Device Versus Intra-Aortic Balloon Pumping for Treatment of Cardiogenic Shock Caused by Myocardial InfarctionJACC, 2008
- Intra-aortic balloon counterpulsation in decompensated cardiomyopathy patients: bridge to transplantation or assist deviceInteractive CardioVascular and Thoracic Surgery, 2006
- In-Hospital Mortality in Patients With Acute Decompensated Heart Failure Requiring Intravenous Vasoactive MedicationsJACC, 2005
- Beat-to-Beat Effects of Intraaortic Balloon Pump Timing on Left Ventricular Performance in Patients With Low Ejection FractionThe Annals of Thoracic Surgery, 2005
- Randomized comparison of intra-aortic balloon support with a percutaneous left ventricular assist device in patients with revascularized acute myocardial infarction complicated by cardiogenic shockEuropean Heart Journal, 2005