Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band
Open Access
- 2 May 2018
- journal article
- research article
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 135,p. e56525
Abstract
A well-defined experimental procedure is put forward to evaluate maximum exposure conditions in a worst-case scenario whilst avoiding the uncertainties caused by the use of personal exposimeters (PEMs) as measuring devices: the body shadow effect (BSE), the limited sensitivity range, and the non-identification of the radiation source. An upper bound for exposure levels to EMF in several indoor enclosures has been measured and simulated. The frequency used for the study is 2.4 GHz, as it is the most commonly used band in indoor communications. Although recorded values are well below the International Commission for Non-Ionizing Radiation Protection (ICNIRP) reference levels, there is a particular need to provide reliable exposure levels within particularly sensitive environments. In terms of electromagnetic field (EMF) exposure, limits established in national and international standards for health protection have been set for unperturbed exposure conditions; that is, for real and objective exposure data that have not been altered in any way.Keywords
This publication has 32 references indexed in Scilit:
- Personal distributed exposimeter for radio frequency exposure assessment in real environmentsBioelectromagnetics, 2013
- Geospatial modelling of electromagnetic fields from mobile phone base stationsScience of The Total Environment, 2013
- Calibration and uncertainties in personal exposure measurements of radiofrequency electromagnetic fieldsBioelectromagnetics, 2011
- Statistical perturbations in personal exposure meters caused by the human body in dynamic outdoor environmentsBioelectromagnetics, 2010
- The association between exposure determined by radiofrequency personal exposimeters and human exposure: A simulation studyBioelectromagnetics, 2010
- EXPERIMENTAL VERIFICATION OF A RADIOFREQUENCY POWER MODEL FOR WI-FI TECHNOLOGYHealth Physics, 2010
- SAR variation study from 300 to 5000 MHz for 15 voxel models including different posturesPhysics in Medicine & Biology, 2010
- Statistical analysis of personal radiofrequency electromagnetic field measurements with nondetectsBioelectromagnetics, 2008
- Potential exposure assessment errors associated with body‐worn RF dosimetersBioelectromagnetics, 2007
- Fabricating data: How substituting values for nondetects can ruin results, and what can be done about itChemosphere, 2006