Using body mass index to estimate individualised patient radiation dose in abdominal computed tomography
Open Access
- 28 November 2018
- journal article
- research article
- Published by Springer Nature in European Radiology Experimental
- Vol. 2 (1) , 38
Abstract
The size-specific dose estimate (SSDE) is a dose-related metrics that incorporates patient size into its calculation. It is usually derived from the volume computed tomography dose index (CTDIvol) by applying a conversion factor determined from manually measured anteroposterior and lateral skin-to-skin patient diameters at the midslice level on computed tomography (CT) localiser images, an awkward, time-consuming, and not highly reproducible technique. The objective of this study was to evaluate the potential for the use of body mass index (BMI) as a size-related metrics alternative to the midslice effective diameter (DE) to obtain a size-specific dose (SSDE) in abdominal CT. In this retrospective study of patients who underwent abdominal CT for the investigation of inflammatory bowel disease, the DE was measured on the midslice level on CT-localiser images of each patient. This was correlated with patient BMI and the linear regression equation relating the quantities was calculated. The ratio between the internal and the external abdominal diameters (DRATIO) was also measured to assess correlation with radiation dose. Pearson correlation analysis and linear regression models were used. There was good correlation between DE and patient BMI (r = 0.88). An equation allowing calculation of DE from BMI was calculated by linear regression analysis as follows: DE = 0.76 (BMI) + 9.4. A weak correlation between radiation dose and DRATIO was demonstrated (r = 0.45). Patient BMI can be used to accurately estimate DE, obviating the need to measure anteroposterior and lateral diameters in order to calculate a SSDE for abdominal CT.Keywords
Funding Information
- Professor Denis O’Sullivan Research Fellowship, University College Cork, Cork, Ireland
This publication has 14 references indexed in Scilit:
- Simplifying Size-Specific Radiation Dose Estimates in Pediatric CTAmerican Journal of Roentgenology, 2015
- Estimating Patient Dose from X-ray Tube Output Metrics: Automated Measurement of Patient Size from CT Images Enables Large-scale Size-specific Dose EstimatesRadiology, 2014
- Size-specific Dose Estimates for Adult Patients at CT of the TorsoRadiology, 2012
- Diagnostic Accuracy of Computed Tomography Using Lower Doses of Radiation for Patients With Crohn's DiseaseClinical Gastroenterology and Hepatology, 2012
- Comparison of topogram‐based body size indices for CT dose consideration and scan protocol optimizationMedical Physics, 2012
- CT Dose Index and Patient Dose: They AreNotthe Same ThingRadiology, 2011
- Patient‐specific radiation dose and cancer risk estimation in CT: Part II. Application to patientsMedical Physics, 2010
- Reliability of doctors' anthropometric measurements to detect obesityPreventive Medicine, 2008
- It is time to retire the computed tomography dose index (CTDI) for CT quality assurance and dose optimizationMedical Physics, 2006
- 16-detector multislice CT: dosimetry estimation by TLD measurement compared with Monte Carlo simulationBritish Journal of Radiology, 2004