Abstract
Engineered timber is an innovative and sustainable construction material, but its uptake has been hindered by concerns about its performance in fire. Current building regulations measure the fire performance of timber using fire resistance tests. In these tests, the charring rate is measured under a series of heat exposures (design fires) and from this the structural performance is deduced. Charring rates are currently only properly understood for the heat exposure of a standard fire, not for other exposures, which restricts the use of performance-based design. This paper studies the charring rates under a range of design fires. We used a multiscale charring model at the microscale (mg-samples), mesoscale (g-samples), and macroscale (kg-samples) for several wood species exposed to different heating regimes and boundary conditions. At the macroscale, the model blindly predicts in-depth temperatures and char depths during standard and parametric fires with an error between 5% and 22%. Comparing simulations of charring under travelling fires, parametric fires, and the standard fire revealed two findings. Firstly, their charring rates significantly differ, with maximum char depths of 42 mm (travelling), 46 mm (parametric), and 59 mm (standard fire), and one (standard fire) to four (travelling fire) charring stages (no charring, slow growth, fast growth, steady-state). Secondly, we observed zero-strength layers (depth between the 200 °C and 300 °C isotherm) of 7 to 12 mm from the exposed surface in travelling fires compared to 5 to 11 mm in parametric fires, and 7 mm in the standard fire. Both traditional design fires and travelling fires, therefore, need to be considered in structural calculations. These results help engineers to move towards performance-based design by allowing the calculation of charring rates for a wide range of design fires. In turn, this will help engineers to build more sustainable and safe structures with timber.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EP/M506345/1)
This publication has 40 references indexed in Scilit:
- A contemporary review of large-scale non-standard structural fire testingFire Science Reviews, 2013
- Travelling fires for structural design–Part I: Literature reviewFire Safety Journal, 2012
- Top ten fundamental challenges of biomass pyrolysis for biofuelsEnergy & Environmental Science, 2012
- Generalized pyrolysis model for combustible solidsFire Safety Journal, 2009
- A model for the oxidative pyrolysis of woodCombustion and Flame, 2009
- Glowing ignition of wood: the onset of surface combustionProceedings of the Combustion Institute, 2005
- Mathematical Model for Wood PyrolysisComparison of Experimental Measurements with Model PredictionsEnergy & Fuels, 2000
- A Generalized Biomass Pyrolysis Model Based on Superimposed Cellulose, Hemicelluloseand Liqnin KineticsCombustion Science and Technology, 1997
- Properties of wood for combustion analysisBioresource Technology, 1991
- Wood gasification at fire level heat fluxesCombustion and Flame, 1987