Designing a Novel Porous Fixation Plate with a Gyroid Lattice Structure for Humerus Fractures Using a Probabilistic Approach
Open Access
- 8 December 2023
- journal article
- research article
- Published by Wiley in Advanced Engineering Materials
- Vol. 26 (2)
Abstract
Conventional fixation plates permanently attached to the body can lead to complications, such as stress shielding and aseptic loosening, due to their contact with the bone, resulting in bone loss. The contact between these solid fixation plates and the bone surface inhibits blood flow, potentially leading to necrosis at the interface. To overcome this challenge, a porous implant featuring a gyroid lattice structure for humerus bone fixation is proposed. However, designing such an implant typically involves deterministic approaches, which do not account for uncertainties in design parameters, loadings on the plate, and additive manufacturing process parameters. Consequently, the actual conditions experienced by the plate may not be accurately modeled. Herein, both deterministic and probabilistic analyses of a porous implant with a gyroid lattice structure positioned on the humeral bone is conducted. The findings are compared to the failure probabilities of both the conventional fixation plate and the optimal plate derived from a previous study. The study reveals that uncertainties in design parameters significantly influence the plate's failure probability compared to deterministic analysis, emphasizing the importance of probability‐based analyses for a reliable plate design.Keywords
Funding Information
- Türkiye Bilimsel ve Teknolojik Araştırma Kurumu (218M425)
This publication has 36 references indexed in Scilit:
- Mechanical properties of open-cell metallic biomaterials manufactured using additive manufacturingMaterials & Design (1980-2015), 2013
- The Improved Biological Performance of a Novel Low Elastic Modulus ImplantPLOS ONE, 2013
- Prediction of the mechanical response of the femur with uncertain elastic propertiesJournal of Biomechanics, 2012
- Finite element analysis using interfragmentary strain theory for the fracture healing process to which composite bone plates are appliedComposite Structures, 2011
- Probabilistic finite element analysis of the uncemented hip replacement—effect of femur characteristics and implant design geometryJournal of Biomechanics, 2010
- Asymptotic homogenisation in linear elasticity. Part I: Mathematical formulation and finite element modellingComputational Materials Science, 2009
- Fixation of Extra-Articular Distal Humerus Fractures Using One Locking Plate Versus Two Reconstruction Plates: A Laboratory StudyJournal of Trauma: Injury, Infection & Critical Care, 2009
- Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysisClinical Biomechanics, 2009
- Are Locking Screws Advantageous with Plate Fixation of Humeral Shaft Fractures? A Biomechanical Analysis of Synthetic and Cadaveric BoneJournal of Orthopaedic Trauma, 2008
- In vivo glenohumeral contact forces—Measurements in the first patient 7 months postoperativelyJournal of Biomechanics, 2007