Magnetic Resonance Imaging of Implantable Cardiac Rhythm Devices at 3.0 Tesla
Author:
- 9 July 2008
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 31 (7) , 795-801
Abstract
Background: A relaxation of the prohibition of scanning cardiac rhythm device patients is underway, largely because of the growing experience of safe scanning events at 1.5T. Magnetic resonance imaging (MRI) at 3T is becoming more common and may pose a different risk profile and outcome of MRI of cardiac device patients. Methods: No restrictions were placed on pacemaker dependency, region scanned, device type, or manufacturer. Sixteen scans at 3T were performed with an electrophysiologist present on 14 patients with a variety of devices from various manufacturers. An “MRI‐S” strategy was used. Multimodal monitoring was required. Device interrogation was performed prior to, immediately after, and 1–3 months after the MRI. For nonpacemaker‐dependent device patients, attempts were made to turn all device features off (with OOO programming the goal) conceptually rendering the device “invisible.” In pacemaker‐dependent patients, the device was programmed to asynchronous mode at highest output for the duration of the scan with the goal of rendering the device conceptually “invulnerable” to MRI effects. The specific absorption rate (SAR) was limited to 2W/kg. Results: All patients were successfully scanned. No arrhythmias were noted. No significant change in the programmed parameters, pacing thresholds, sensing, impedance, or battery parameters was noted. The insertable loop recorder (ILR) recorded prolonged artifactual asystole during MRI. One patient noted chest burning during the scan. Conclusions: Device patients may undergo carefully tailored 3T MRI scans when pre‐MRI reprogramming of the device occurs in conjunction with extensive monitoring, supervision, and follow‐up.Keywords
This publication has 34 references indexed in Scilit:
- ACR Guidance Document for Safe MR Practices: 2007American Journal of Roentgenology, 2007
- MR in Patients with Pacemakers and ICDs: Defining the IssuesJournal of Cardiovascular Magnetic Resonance, 2007
- Clinical Utility and Safety of a Protocol for Noncardiac and Cardiac Magnetic Resonance Imaging of Patients With Permanent Pacemakers and Implantable-Cardioverter Defibrillators at 1.5 TeslaCirculation, 2006
- Potential harmful effects of magnetic resonance imaging in pacemaker patients should not be underestimatedEP Europace, 2006
- Safe, sensible, sagacious: responsible scanning of pacemaker patientsEuropean Heart Journal, 2005
- Government Viewpoint: U.S. Food & Drug Administration: Pacemakers, ICDs and MRIPacing and Clinical Electrophysiology, 2005
- Outcome of Magnetic Resonance Imaging (MRI) in Selected Patients with Implantable Cardioverter Defibrillators (ICDs)Pacing and Clinical Electrophysiology, 2005
- Polymorphic Ventricular Tachycardia Induced by Left Ventricular PacingCirculation, 2004
- Pacemaker induced ventricular fibrillation in coronary care unitsBMJ, 2004
- Pacing in High Field Cardiac Magnetic Resonance Imaging:. Implantation of a Permanent Pacemaker into a RatPacing and Clinical Electrophysiology, 2004