Mobile-Bearing Total Knee Arthroplasty
- 1 November 2005
- journal article
- section i
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 440 (&NA;) , 88-95
Abstract
In vivo kinematics were determined during a weightbearing deep knee bend in 39 patients implanted with four different designs of mobile-bearing total knee arthroplasty to assess polyethylene bearing mobility patterns and magnitudes. The femoral and tibial components and mobile polyethylene insert (implanted with four tantalum beads) were overlaid onto the fluoroscopic images using a three-dimensional model-fitting technique to determine bearing mobility. Three of the four designs were tested at a single time interval while one was evaluated at two postoperative intervals, (12 months apart) to assess changes in bearing mobility with time. All patients had polyethylene bearing rotation relative to the tibial tray and minimal rotation relative to the femoral component. The average maximum amounts of bearing rotation ranged from 8.4° to 10.3° (range, 3.0°-20.1°). In patients evaluated at two time intervals, the average maximum bearing rotation increased from 8.5° (range, 3.4°-15.5°) at 3 months to 9.8° (range, 48°-14.1°) 15 months postoperatively. The presented data demonstrates polyethylene bearing mobility occurs following mobile-bearing total knee arthroplasty and mobility is maintained during the time interval tested. The presence of bearing mobility should result in lower contact stresses reducing the potential for polyethylene wear.Keywords
This publication has 28 references indexed in Scilit:
- The influence of design, materials and kinematics on the in vitro wear of total knee replacementsJournal of Biomechanics, 2005
- A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy imagesIEEE Transactions on Medical Imaging, 2003
- In Vivo Fluoroscopic Analysis Of Fixed-Bearing Total Knee ReplacementsClinical Orthopaedics and Related Research, 2003
- Mobility and Contact Mechanics of a Rotating Platform Total Knee ReplacementClinical Orthopaedics and Related Research, 2001
- In Vivo Anteroposterior Femorotibial Translation of Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1998
- Three-dimensional kinematics of the human knee during walkingJournal of Biomechanics, 1992
- Motion of the knee after condylar resurfacing—An in vivo studyJournal of Biomechanics, 1991
- Abnormal kinematics of the artificial knee: Roentgen stereophotogrammetric analysis of 10 Miller-Galante and five New Jersey LCS kneesActa Orthopaedica, 1991
- Three-dimensional dynamic motion analysis of the anterior cruciate ligament deficient knee jointThe American Journal of Sports Medicine, 1989
- The “Screw-Home” Movement in the Knee-JointActa Orthopaedica, 1966