Femoral surface strain in intact composite femurs: a custom computer analysis of the photoelastic coating technique
Authors:
- M.J. GreculaMGM.J. Grecula
- R.P. MorrisRMR.P. Morris
- J.C. LaughlinJLJ.C. Laughlin
- W.L. BufordWBW.L. Buford
- R.M. PatrersonRPR.M. Patrerson
- 1 July 2000
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 47 (7) , 926-933
Abstract
Understanding how forces are distributed through the proximal femur has many clinical applications for surgeons, researchers, and prosthetic designers. A new system for two-dimensional analysis of femoral surface strain was developed and applied to intact composite femurs. The photoelastic coating method was used to resolve the surface strain under axial loading, and strain analysis was performed using digital imaging of the strain patterns and original computer programs. The technique provides qualitative and quantitative data that describes overall femoral surface strains more completely than previous point analysis and strain gauge techniques. Results from repeated testing found the photoelastic process, computer imaging and computer analysis of strain areas to be statistically repeatable.Keywords
This publication has 19 references indexed in Scilit:
- Mechanical validation of whole bone composite femur modelsJournal of Biomechanics, 1996
- Closeness of fit of uncemented stems improves the strain distribution in the femurJournal of Orthopaedic Research, 1995
- Strain distribution in the proximal femur with flexible composite and metallic femoral components under axial and torsional loadsJournal of Biomedical Materials Research, 1993
- A comparison of cortical strain after cemented and press-fit proximal and distal femoral replacementJournal of Orthopaedic Research, 1992
- Determinants of Stress ShieldingClinical Orthopaedics and Related Research, 1992
- Producing and Avoiding Stress ShieldingClinical Orthopaedics and Related Research, 1992
- Technical note. Comparison of the deformation response of synthetic and cadaveric femora during simulated one‐legged stanceJournal of Applied Biomaterials, 1991
- An evaluation of three loading configurations for the in vitro testing of femoral strains in total hip arthroplastyJournal of Orthopaedic Research, 1991
- Effect of press-fit femoral stems on strains in the femurThe Journal of Arthroplasty, 1990
- Strain Analysis of the Proximal Femur After Total Hip Replacement1987