Bone level changes at axial‐ and non‐axial‐positioned implants supporting fixed partial dentures. A 5‐year retrospective longitudinal study
- 30 June 2007
- journal article
- research article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 18 (5) , 585-590
Abstract
Aim: The aim of this study was to retrospectively analyze the potential influence of implant inclination on marginal bone loss at freestanding, implant‐supported, fixed partial dentures (FPDs) over a 5‐year period of functional loading.Material and methods: The material comprised 38 periodontally treated, partially dentate patients with a total of 42 free‐standing FPDs supported by implants of the Astra Tech System®. Mesio‐distal inclination of the implants in relation to a vertical axis perpendicular to the occlusal plane was measured with a protractor on standardized photographs of the master cast. The two tail quartiles of the distribution of the implants with regard to the implant inclination were defined as axial‐positioned (mean 2.4°; range 0–4°) and non‐axial‐positioned implants (mean 17.1°; range 11–30°), respectively. For FPDs supported by two implants, both the mesial–distal and buccal–lingual inter‐implant inclination was measured. The primary outcome variable was change in peri‐implant bone level from the time of FPD placement to the 5‐year follow‐up examination. Comparison between axial‐ and non‐axial‐positioned implants was performed by the use of a Mann–Whitney U‐test. Spearman's correlation analysis was used to analyze relationships between inter‐implant inclination (mesial–distal and buccal–lingual) and 5‐year bone level change on the FPD level.Results: The 5‐year mean bone level change amounted to 0.4 mm (SD 0.97) for the axial and 0.5 mm (0.95) for non‐axial‐positioned implants (P>0.05). For the FPDs supported by two implants, the mean inter‐implant inclination was 9.2° (1–36°) in the mesial–distal direction and 6.7° (0–24°) in the buccal–lingual direction. Correlation analysis revealed lack of statistically significant correlation between inter‐implant inclination (mesial–distal and buccal–lingual) and 5‐year bone level change (r=−0.19 and r=−0.32, respectively).Conclusion: The study failed to support the hypothesis that implant inclination has an effect on peri‐implant bone loss.Keywords
This publication has 26 references indexed in Scilit:
- Oral rehabilitation with implant‐supported fixed partial dentures in periodontitis‐susceptible subjectsJournal of Clinical Periodontology, 2004
- Does excessive occlusal load affect osseointegration? An experimental study in the dogClinical Oral Implants Research, 2004
- Long‐term implant prognosis in patients with and without a history of chronic periodontitis: a 10‐year prospective cohort study of the ITI® Dental Implant SystemClinical Oral Implants Research, 2003
- Changes in Peri‐Implant Tissues Subjected to Orthodontic Forces and Ligature Breakdown in MonkeysJournal of Periodontology, 1998
- Histological evaluation of peri-implant bone at implants subjected to occlusal overload or plaque accumulationClinical Oral Implants Research, 1997
- Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys.Clinical Oral Implants Research, 1996
- A Three‐Dimensional Finite Element Stress Analysis of Angled Abutments for an Implant Placed in the Anterior MaxillaJournal of Prosthodontics, 1995
- An Assessment of Survival Rates and Within-patient Clustering of Failures for Endosseous Oral ImplantsJournal of Dental Research, 1993
- Fixture design and overload influence marginal bone loss and future success in the Brånemark® systemClinical Oral Implants Research, 1992
- Three-dimensional Stress Distribution Around a Dental Implant at Different Stages of Interface DevelopmentJournal of Dental Research, 1983