Assessment of Stenosis: Implications of Variability of Doppler Measurements in Normal-appearing Carotid Arteries
Authors:
- Barbara S. HertzbergBHBarbara S. Hertzberg
- Mark A. KliewerMKMark A. Kliewer
- Barbara A. CarrollBCBarbara A. Carroll
- 1 August 1999
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 212 (2) , 493-498
Abstract
To examine the variability of Doppler measurements along the extra-cranial courses of the nondiseased common carotid artery (CCA) and internal carotid artery (ICA) and determine the effect of this variability on assessment of carotid arterial stenosis. During the study period, 580 patients were referred for carotid arterial ultrasonography (US), including Doppler measurements of flow velocities in the proximal, middle, and distal portions of the CCA, in the bulb, and in the proximal and distal portions of the ICA. Eighty-five patients (average age, 59 years) with normal ICAs and CCAs formed the cohort for this study. The range of peak systolic velocity (PSV) measurement (maximum minus minimum) averaged 20 cm/sec +/- 13 in the CCA and 15 cm/sec +/- 13 in the ICA. ICA/CCA velocity ratios varied, depending on the CCA measurement location. In five arteries, PSV ratios exceeded a threshold of 1.8 (suggesting > or = 60% stenosis); in 23 arteries, end diastolic velocity ratios exceeded a threshold of 2.4 (also suggesting > or = 60% stenosis). Right-to-left CCA PSV ratios were abnormal in up to 26 patients (suggesting > 50% ICA stenosis), depending on where CCA measurements were obtained. When the CCA ratios were obtained at the same level, 16 were in the abnormal range. Variability of Doppler measurements in the CCA and ICA in patients without visible disease is substantial and could lead to inaccuracies in carotid arterial stenosis assessment.Keywords
This publication has 22 references indexed in Scilit:
- New Doppler parameters for carotid stenosisSeminars in Ultrasound, CT and MRI, 1997
- Determination of sixty percent or greater carotid artery stenosis by duplex Doppler ultrasonographyJournal of Vascular Surgery, 1995
- Duplex Accuracy Compared with Angiography in the Veterans Affairs Cooperative Studies Trial for Symptomatic Carotid StenosisNeurosurgery, 1995
- Detection and quantification of carotid artery stenosis: efficacy of various Doppler velocity parameters.American Journal of Roentgenology, 1993
- Duplex carotid sonography. Peak systolic velocity in quantifying internal carotid artery stenosis.Journal of Ultrasound in Medicine, 1990
- Diagnostic criteria for carotid duplex sonographyAmerican Journal of Roentgenology, 1988
- Use of diastolic velocity ratios to predict significant carotid artery stenosis.Stroke, 1988
- Carotid duplex sonography: a multicenter recommendation for standardized imaging and Doppler criteria.RadioGraphics, 1988
- Spectrum analysis in carotid sonographyUltrasound in Medicine & Biology, 1987
- Duplex ultrasound scanning of the carotid arteries with velocity spectrum analysis.Radiology, 1983