Percutaneous carotid artery access in infants < 3 months of age
- 23 December 2015
- journal article
- pediatric and-congenital-heart-disease
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 87 (4) , 757-761
Abstract
Background: Carotid artery access in infants with congenital heart disease undergoing cardiac catheterization via a surgical cut down has been well described. There is a paucity of information regarding percutaneous carotid artery (CA) access in infants <3 months.Methods: A retrospective review of infants <3 months of age undergoing cardiac catheterization via percutaneous CA approach was performed after IRB approval. Between January 2012 and May 2015, 18 patients underwent 20 procedures; median age 13 days (2–77); median weight 3.3 kg (1.6–5). Procedures performed were patent ductus arteriosus (PDA) stenting (8), modified blalock taussig (BT) shunt stenting (3), balloon aortic valvuloplasty (6), and balloon angioplasty of coarctation (3).Results: Percutaneous access was obtained with a Doppler needle under ultrasound guidance into the right (16) and left CA (4). Sheath size used was 4 Fr (17), 5 Fr (2), and 6 Fr (1). Median time to sheath insertion was 6.5 min (2–20). Percutaneous access was obtained successfully in all cases. There were no major procedural complications. There were two minor complications; hypotension, and ductal spasm. Hemostasis was achieved by manual compression; median time was 14.5 min (8–36). There were two post‐procedural complications involving development of CA pseudo aneurysms that were repaired surgically. Post‐procedure CA patency was documented by angiography (3), MRA (3), or vascular ultrasound (14). There were no documented arterial occlusions.Conclusion: Our experience suggests that percutaneous CA access in infants <3 months of age is safe and feasible with preserved vascular patency and no neurological adverse events.Keywords
This publication has 20 references indexed in Scilit:
- Adverse event rates in congenital cardiac catheterization — A multi‐center experienceCatheterization and Cardiovascular Interventions, 2009
- The Anatomic Variations of the Circle of Willis in Preterm-at-Term and Term-Born Infants: An MR Angiography Study at 3TAmerican Journal of Neuroradiology, 2009
- Does anatomical completeness of the circle of Willis correlate with sufficient cross-perfusion during unilateral cerebral perfusion?☆European Journal of Cardio-Thoracic Surgery, 2008
- Axillary artery approach for balloon valvoplasty in young infants with severe aortic valve stenosis: Medium‐term resultsCatheterization and Cardiovascular Interventions, 2006
- Vascular ultrasound imaging to study immediate postcatheterization vascular complications in childrenCatheterization and Cardiovascular Interventions, 2006
- Critical Aortic Stenosis in Early Infancy: Surgical Treatment for Residual Lesions After Balloon DilationThe Annals of Thoracic Surgery, 2005
- Two-dimensional and Doppler ultrasound evaluation of femoral arteries in infants after cardiac catheterizationThe American Journal of Cardiology, 1995
- Early complications of interventional balloon catheterisation in infants and children.Heart, 1991
- Carotid artery approach for balloon dilation of aortic valve stenosis in the neonate: A preliminary reportJACC, 1990
- Acute complications of catheter therapy for congenital heart diseaseThe American Journal of Cardiology, 1987