3DMR osseous reconstructions of the shoulder using a gradient-echo based two-point Dixon reconstruction: a feasibility study
- 25 July 2012
- journal article
- research article
- Published by Springer Nature in Skeletal Radiology
- Vol. 42 (3) , 347-352
Abstract
Objective To create 3DMR osseous models of the shoulder similar to 3DCT models using a gradient-echo-based two-point/Dixon sequence. Materials and methods CT and 3TMR examinations of 7 cadaveric shoulders were obtained. Glenoid defects were created in 4 of the cadaveric shoulders. Each MR study included an axial Dixon 3D-dual-echo-time T1W-FLASH (acquisition time of 3 min/30 s). The water-only image data from the Dixon sequence and CT data were post-processed using 3D software. The following measurements were obtained on the shoulders: surface area (SA), height/width of the glenoid and humeral head, and width of the biceps groove. The glenoid defects were measured on imaging and compared with measurements made on en face digital photographs of the glenoid fossae (reference standard). Paired t tests/ANOVA were used to assess the differences between the imaging modalities. Results The differences between the glenoid and humeral measurements were not statistically significant (cm): glenoid SA 0.12 ± 0.04 (p = 0.45) and glenoid width 0.13 ± 0.06 (p = 0.06) with no difference in glenoid height measurement; humeral head SA 0.07 ± 0.12 (p = 0.42), humeral head height 0.03 ± 0.06 (p = 0.42), humeral head width 0.07 ± 0.06(p = 0.18), and biceps groove width 0.02 ± 0.01 (p = 0.07). The mean/standard deviation difference between the reference standard and 3DMR measurements was 0.25 ± 0.96 %/0.30 ± 0.14 mm; 3DCT 0.25 ± 0.96 /0.75 ± 0.39 mm. There was no statistical difference between the measurements obtained on 3DMR and 3DCT (percentage, p = 0.45; mm, p = 0.20). Conclusion Accurate 3D osseous models of the shoulder can be produced using a 3D two-point/Dixon sequence and can be added to MR examinations with a minor increase in imaging time, used to quantify glenoid loss, and may eliminate the need for pre-surgical CT examinations.Keywords
This publication has 21 references indexed in Scilit:
- Quantification of the accuracy of MRI generated 3D models of long bones compared to CT generated 3D modelsMedical Engineering & Physics, 2011
- Femoral Tunnel Placement During Anterior Cruciate Ligament ReconstructionThe American Journal of Sports Medicine, 2009
- IMAGE FUSION OF COMPUTED TOMOGRAPHIC AND MAGNETIC RESONANCE IMAGES FOR THE DEVELOPMENT OF A THREE‐DIMENSIONAL MUSCULOSKELETAL MODEL OF THE EQUINE FORELIMBVeterinary Radiology & Ultrasound, 2006
- GLENOID RIM MORPHOLOGY IN RECURRENT ANTERIOR GLENOHUMERAL INSTABILITYJournal of Bone and Joint Surgery, 2003
- Glenohumeral articular contact areas and pressures following labral and osseous injury to the anteroinferior quadrant of the glenoidJournal of Shoulder and Elbow Surgery, 2002
- Quantifying glenoid bone loss arthroscopically in shoulder instabilityArthroscopy, 2002
- Uniform Fat Suppression in Hands and Feet through the Use of Two-Point Dixon Chemical Shift MR ImagingRadiology, 1999
- Compositional changes in vertebral bone marrow during treatment for acute leukemia: assessment with quantitative chemical shift imaging.Radiology, 1992
- Quantitative chemical shift imaging of vertebral bone marrow in patients with Gaucher disease.Radiology, 1992
- Magnetic resonance imaging of bone marrow: diagnostic value in diffuse hematologic disorders.1990