Short-term Intraocular Pressure Spikes Induced by Pneumoperitoneum are Safe for the Optic Nerve in a Healthy Eye
Open Access
- 1 January 2018
- journal article
- Published by Touch Medical Media, Ltd. in European Ophthalmic Review
- Vol. 12 (1) , 61
Abstract
The aim of this study was to determine the effects of the pneumoperitoneum used in colorectal procedures on peripapillary retinal nerve fibre layer (RNFL) thickness. We also analysed the dynamics of ocular anterior segment structures. In this prospective clinical pilot study, 29 patients aged between 45 and 85 years old underwent laparoscopic surgery for selected colorectal diseases. The pneumoperitoneum induced a mean intraocular pressure (IOP) increase of 4 mmHg. Visual acuity, IOP, corneal thickness, angle opening distance (AOD) and the trabeculo-iris space area (TISA) at 500 microns and 750 microns anterior to the scleral spur, RNFL thickness and visual field were measured before and after surgery using Sloan charts, Visante™ optical coherence tomography (OCT) (Zeiss, Oberkochen, Germany), Spectralis® OCT (Heidelberg Engineering, Heidelberg, Germany) and Humphrey Visual Field System® (Zeiss, Oberkochen, Germany). Patients were categorised in two groups to understand the behaviour of IOP: in group one (n=17), patients were in Trendelenburg position; in group two (n=12), patients were in reverse Trendelenburg position. The IOP was measured during surgery by the Icare® Tonometer (Icare, Vantaa, Finland) according to a standardised protocol; the IOP was measured before and after surgery by Goldmann applanation tonometer (Haag-Streit, Koniz, Switzerland). Patients with previous diagnosis of both open or angle-closure glaucoma or anterior segment anomalies were excluded. No statistically significant differences in increase of IOP were found between the two groups (p>0.05); no statistically significant differences in RNFL thickness, visual field, AOD and TISA were found before and after surgery in all patients (p>0.05). In our study we have demonstrated that a mean IOP increase of 4 mmHg over a short period of time is safe for a healthy optic nerve.Keywords
Funding Information
- No funding was received in the publication of this article.
This publication has 17 references indexed in Scilit:
- CorrespondenceRetina, 2015
- Prospective Retinal and Optic Nerve Vitrectomy Evaluation (PROVE) StudyOphthalmology, 2014
- PREVALENCE OF OPEN ANGLE GLAUCOMA IN VITRECTOMIZED EYESRetina, 2014
- Rates of Retinal Nerve Fiber Layer Thinning in Glaucoma Suspect EyesOphthalmology, 2014
- Intraocular pressure variation during colorectal laparoscopic surgery: standard pneumoperitoneum leads to reversible elevation in intraocular pressureSurgical Endoscopy, 2013
- Raised intraocular pressure (IOP) and perioperative visual loss in laparoscopic colorectal surgery: a catastrophe waiting to happen? A systematic review of evidence from other surgical specialitiesTechniques in Coloproctology, 2012
- Validity and Limits of the Rebound Tonometer (ICare®): Clinical StudyEuropean Journal of Ophthalmology, 2010
- Reproducibility of Anterior Chamber Angle Measurements Obtained with Anterior Segment Optical Coherence TomographyInvestigative Ophthalmology & Visual Science, 2007
- Comparison of ICare Tonometer with Goldmann Applanation Tonometer in Glaucoma PatientsJournal of Glaucoma, 2006
- Laparoscopic Total Mesorectal ExcisionAnnals of Surgery, 2003