Feasibility of Employing Model-Based Optimization of Pulse Amplitude and Electrode Distance for Effective Tumor Electropermeabilization
Authors:
- Davorka SelDSDavorka Sel
- Alenka Maek LebarALAlenka Maek Lebar
- Damijan MiklavcicDMDamijan Miklavcic
- 16 April 2007
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 54 (5) , 773-781
Abstract
In electrochemotherapy (ECT) electropermeabilization, parameters (pulse amplitude, electrode setup) need to be customized in order to expose the whole tumor to electric field intensities above permeabilizing threshold to achieve effective ECT. In this paper, we present a model-based optimization approach toward determination of optimal electropermeabilization parameters for effective ECT. The optimization is carried out by minimizing the difference between the permeabilization threshold and electric field intensities computed by finite element model in selected points of tumor. We examined the feasibility of model-based optimization of electropermeabilization parameters on a model geometry generated from computer tomography images, representing brain tissue with tumor. Continuous parameter subject to optimization was pulse amplitude. The distance between electrode pairs was optimized as a discrete parameter. Optimization also considered the pulse generator constraints on voltage and current. During optimization the two constraints were reached preventing the exposure of the entire volume of the tumor to electric field intensities above permeabilizing threshold. However, despite the fact that with the particular needle array holder and pulse generator the entire volume of the tumor was not permeabilized, the maximal extent of permeabilization for the particular case (electrodes, tissue) was determined with the proposed approach. Model-based optimization approach could also be used for electro-gene transfer, where electric field intensities should be distributed between permeabilizing threshold and irreversible threshold-the latter causing tissue necrosis. This can be obtained by adding constraints on maximum electric field intensity in optimization procedureKeywords
This publication has 48 references indexed in Scilit:
- The Course of Tissue Permeabilization Studied on a Mathematical Model of a Subcutaneous Tumor in Small AnimalsIEEE Transactions on Biomedical Engineering, 2005
- Sequential Finite Element Model of Tissue ElectropermeabilizationIEEE Transactions on Biomedical Engineering, 2005
- Effectiveness of tumor electrochemotherapy as a function of electric pulse strength and durationBioelectrochemistry, 2005
- Electric field of a six-needle array electrode used in drug and dna delivery in vivo: analytical versus numerical solutionIEEE Transactions on Biomedical Engineering, 2003
- Quantitative model of small molecules uptake after in vitro cell electropermeabilizationBioelectrochemistry, 2003
- A validated model of in vivo electric field distribution in tissues for electrochemotherapy and for DNA electrotransfer for gene therapyBiochimica et Biophysica Acta (BBA) - General Subjects, 2000
- In vivo electroporation of skeletal muscle: threshold, efficacy and relation to electric field distributionBiochimica et Biophysica Acta (BBA) - General Subjects, 1999
- Determination of Optimal Parameters for in Vivo Gene Transfer by Electroporation, Using a Rapid in Vivo Test for Cell PermeabilizationBiochemical and Biophysical Research Communications, 1999
- Electroporation therapy: a new approach for the treatment of head and neck cancerIEEE Transactions on Biomedical Engineering, 1999
- Electropermeabilization of mammalian cells. Quantitative analysis of the phenomenonBiophysical Journal, 1990