Monte Carlo calculations of the absorbed dose and energy dependence of plastic scintillators
Authors:
- A. Sam BeddarA. Sam Beddar
- Tina Marie BriereTBTina Marie Briere
- Firas A. MourtadaFMFiras A. Mourtada
- Oleg N. VassilievOVOleg N. Vassiliev
- H. Helen LiuHLH. Helen Liu
- Radhe MohanRMRadhe Mohan
- 13 April 2005
- journal article
- Published by Wiley in Medical Physics
- Vol. 32 (5) , 1265-1269
Abstract
Detector systems using plastic scintillators can provide instantaneous measurements with high spatial resolution in many applications including small field and high dose gradient field applications. Energy independence and water equivalence are important dosimetric properties that determine whether a detector will be useful in a clinical setting. Using Monte Carlo simulations, we calculated the energy dependence of plastic scintillators when exposed to photon beams in the radiotherapeutic range. These calculations were performed for a detector comprised of a BC-400 plastic scintillator surrounded by a polystyrene wall. Our results showed the plastic scintillation detector to be nearly energy independent over a range of energies from 0.5 to 20 MeV. The ratio of the dose absorbed by the scintillator to that absorbed by water was nearly a constant, approximately equal to 0.98 over the entire energy range of interest. These results confirm the water equivalence of the plastic scintillation detector and are in very good agreement with earlier results obtained using Burlin cavity theory.Keywords
This publication has 25 references indexed in Scilit:
- Scintillating fiber dosimeter for radiation therapy acceleratorIEEE Transactions on Nuclear Science, 2002
- In vivo quantification of localized neuronal activation and inhibition in the rat brain using a dedicated high temporal-resolution β + -sensitive microprobeProceedings of the National Academy of Sciences, 2002
- A miniature "scintillator-fiberoptic-PMT" detector system for the dosimetry of small fields in stereotactic radiosurgeryIEEE Transactions on Nuclear Science, 2001
- Dosimetry characterization of catheter‐based vascular brachytherapy source wireMedical Physics, 2000
- SIC, an intracerebral radiosensitive probe for in vivo neuropharmacology investigations in small laboratory animals: theoretical considerations and practical characteristicsIEEE Transactions on Nuclear Science, 2000
- A new scintillator detector system for the quality assurance of60Co and high-energy therapy machinesPhysics in Medicine & Biology, 1994
- Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerationsPhysics in Medicine & Biology, 1992
- Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurementsPhysics in Medicine & Biology, 1992
- Structure and Operation of the ITS Code System1988
- A General Theory of Cavity IonisationBritish Journal of Radiology, 1966