UV Disinfection of Wastewater: Probabilistic Approach to Design
Authors:
- 1 December 1996
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 122 (12) , 1078-1084
Abstract
In the design of an ultraviolet (UV) disinfection system for a wastewater treatment plant (WWTP), the number of lamps necessary to meet the permit requirements must be determined. Factors influencing the required number of lamps include the wastewater characteristics, the variability in the wastewater characteristics, and the permit requirements. In this paper, a probabilistic approach is described for designing a disinfection facility and is contrasted with the conventional, nonprobabilistic approach. The approaches are illustrated using data collected from both collimated beam and pilot-scale UV disinfection studies conducted at a major Northern California WWTP. The advantages and disadvantages of each approach are discussed along with criteria for selecting a suitable approach for a particular WWTP.Keywords
This publication has 3 references indexed in Scilit:
- Ultraviolet disinfection of secondary wastewater effluents: prediction of performance and designWater Environment Research, 1996
- Bioassay and dose measurement in UV disinfectionApplied and Environmental Microbiology, 1983
- Light intensity profiles in a perfectly mixed photoreactorAIChE Journal, 1970