On‐Desk Model‐Based Study for Evaluating the Effect of Squeezing the Arteries in the Forearm on the Bioimpedance and Pressure of Blood
Open Access
- 1 January 2023
- journal article
- research article
- Published by Wiley in Journal of Sensors
- Vol. 2023 (1)
Abstract
Background. Today, central aortic pressure (CAP) is measured through the invasive procedure of angiography. The only feasible alternative is applanation tonometry, requiring experienced staff to perform reliable measurements. The method of measuring the electrical bioimpedance (EBI) from the wrist gives promising results in estimating the CAP. However, the origin of the EBI data, its quality, and approaches to acquiring the signal are still vague. This study is aimed at determining the dependency of EBI of blood on the diameter, branching, and hindering the blood flow by squeezing the vessel. Methods. An on‐desk hydraulic and mechanical pipe system that imitates the arterial tree in the forearm with the modulated flow of saline solution to imitate the pulsating blood was constructed. The setup was verified in the simulation model. The flexible and rigid pipes were squeezed at selected locations of radial and ulnar arteries, and the superficial palmar arc and the pressure with impedance were measured. Results. The multifaceted effect of squeezing the selected locations of arteries in the forearm on the measured EBI and pressure was verified. The effect of arterial stiffening was verified, revealing a very strong inverse correlation of the time‐varying impedance (ΔZ(t)) of rigid pipe compared to the measured data of the wrist. Conclusion. To gain the highest magnitude of ΔZ(t), our research suggests applying pressure on the radial artery and measuring the EBI of the ulnar artery. Our results propose physiology‐based suggestions to increase the sensitivity of measured EBI of the pulse wave, constituting a base for designing novel wearable monitoring devices and algorithms for CAP estimation.Keywords
Funding Information
- Eesti Teadusagentuur (Mobera20, PRG1483, EAG34, IUT19-11)
This publication has 32 references indexed in Scilit:
- Noninvasive Measurement of Central Vascular Pressures With Arterial Tonometry: Clinical Revival of the Pulse Pressure Waveform?Mayo Clinic Proceedings, 2010
- Pulse pressure—a review of mechanisms and clinical relevanceJACC, 2001
- Capillaroscopy and the measurement of capillary pressureBritish Journal of Clinical Pharmacology, 2000
- The vascular systemJournal of Pharmacological and Toxicological Methods, 2000
- The influence of the non-Newtonian properties of blood on the flow in large arteries: unsteady flow in a 90° curved tubeJournal of Biomechanics, 1999
- Effect of blood's velocity on blood resistivityIEEE Transactions on Instrumentation and Measurement, 1998
- Decreased hydrodynamic resistance in the two-phase flow of blood through small vertical tubes at low flow rates.Circulation Research, 1991
- A photoelectric plethysmograph for the measurement of cutaneous blood flowPhysics in Medicine & Biology, 1974
- Effect of diluents on blood clot lysisJournal of Clinical Pathology, 1967
- Electrical Impedance PlethysmographyCirculation, 1950