Accuracy of Full-Arch Intraoral Scans Versus Conventional Impression: A Systematic Review with a Meta-Analysis and a Proposal to Standardise the Analysis of the Accuracy
Top Cited Papers
Open Access
- 27 December 2024
- journal article
- review article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (1) , 71
Abstract
Objectives: The aim of this study was to systematically revise the state of art of the accuracy of digital and conventional impressions in clinical full-arch scenarios. Methods: Electronic and manual searches were conducted up to December 2024. Only trials comparing the accuracy of digital versus conventional impressions were selected by two independent reviewers. Accuracy was evaluated by analysing the fit of the prostheses obtained through conventional workflows and those obtained from digital workflows using intraoral scanners. Alternatively, accuracy was assessed by comparing the standard tessellation language data acquired from intraoral scanning with those obtained from scanning the physical model. The risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool. Meta-analysis was conducted to pool the mean differences from the included studies, with heterogeneity tested by Cochran’s Q test and quantified by the I2 index. Results: We included 9 relevant studies from a total of 2535 identified studies. The risk of bias was evaluated as low, and the main results of all the included articles reported similar accuracy between digital and conventional impressions. Random effects meta-analysis resulted in a pooled mean difference of 152.46 (95% C.I. = 76.46–228.46, p-value < 0.001, I2 = 93.48%). Conclusions: In conclusion, the results of the present systematic review reveal contradictory findings regarding the accuracy of digital impressions. However, most studies analysing the clinical performance of prostheses obtained through digital impressions suggest that their accuracy falls within clinically acceptable thresholds. Future research should report comparable outcomes and focus attention on linear deviations, comparing differences between conventional and digital impressions not in absolute terms, but relative to the distance measured.Keywords
This publication has 36 references indexed in Scilit:
- Effect of auxiliary geometric devices on the accuracy of intraoral scans in full-arch implant-supported rehabilitations: An in vitro studyJournal of Dentistry, 2024
- Linear Accuracy of Intraoral Scanners for Full-Arch Impressions of Implant-Supported Prostheses: A Systematic Review and Meta-AnalysisEuropean Journal of Dentistry, 2023
- Trueness of a device for intraoral scanning to capture the angle and distance between implants in edentulous mandibular archesThe Journal of Prosthetic Dentistry, 2022
- Fit of complete-arch implant-supported prostheses produced from an intraoral scan by using an auxiliary device and from an elastomeric impression: A pilot clinical trialThe Journal of Prosthetic Dentistry, 2022
- Computerized optical impression making of edentulous jaws – An in vivo feasibility studyJournal of Prosthodontic Research, 2020
- Accuracy and practicality of intraoral scanner in dentistry: A literature reviewJournal of Prosthodontic Research, 2020
- Clinical outcomes of using a prosthetic protocol to rehabilitate tissue-level implants with a convergent collar in the esthetic zone: A 3-year prospective studyThe Journal of Prosthetic Dentistry, 2020
- Improved digital impressions of edentulous areasThe Journal of Prosthetic Dentistry, 2017
- Passive Fit in Screw Retained Multi-unit Implant Prosthesis Understanding and Achieving: A Review of the LiteratureThe Journal of Indian Prosthodontic Society, 2013
- The accuracy of implant impressions: A systematic reviewThe Journal of Prosthetic Dentistry, 2008