A Smart Energy Assistant to Assess and Improve the Field Performance of Air-source Heat Pumps in Cold Climates
Authors:
- Hyeongseok LeeHLHyeongseok Lee
- Jaehyun GoJGJaehyun Go
- Hemanth DevarapalliHDHemanth Devarapalli
- Denison GuvenozDGDenison Guvenoz
- Elisa Quaresma RagoneERElisa Quaresma Ragone
- Nadine Amr Mahmoud AminNANadine Amr Mahmoud Amin
- Jiayu GengJGJiayu Geng
- Tianyi LiTLTianyi Li
- Rebecca E. CiezRCRebecca E. Ciez
- Torsten ReimerTorsten Reimer
- Julia Taylor RayzJRJulia Taylor Rayz
- James E. BraunJBJames E. Braun
Preprint
- 7 July 2026
- preprint
- Published by Elsevier in SSRN Electronic Journal
Abstract
This paper presents a field study aiming to understand and improve the energy and thermal comfort performance of air-source heat pumps (ASHPs) in cold climates. The study was conducted in a residential community of 22 single-family homes in Indianapolis, Indiana, equipped with smart thermostats, circuit-level power meters, and indoor temperature sensors. Field measurements and resident interviews were first used to characterize thermostat adjustments and their implications for heating-related electricity use. Baseline data revealed that heating-related electricity use varied significantly, by up to a factor of two, across physically similar homes, indicating that ASHP field performance was shaped not only by weather, equipment, and envelope characteristics, but also by how residents operated their thermostats and supplemental heating devices. A Smart Energy Assistant was then developed for the first time, to detect energy-inefficient thermostat adjustments and implement targeted control actions, while communicating each action and allowing residents to cancel or override it. These control actions were designed to reduce unnecessary auxiliary heat use, avoid inefficient recovery loads, improve temperature distribution, and encourage more efficient use of the central heat pump system. During the two-month deployment, the Smart Energy Assistant generated 1,643 actions across 22 homes, with 88% overall acceptance rate, but with uneven distribution across homes. Overall, the findings indicate that improving ASHP performance in occupied homes requires both better understanding of resident thermostat adjustments and equipment control strategies as well as transparent communication and consideration of resident thermal comfort and agency.Keywords
This publication has 18 references indexed in Scilit:
- Consistency is key: Evaluation of and recommendations for thermostat usability testingBuilding and Environment, 2025
- Experimental study on the operating performance of the air source heat pump (ASHP) with variable outdoor airflow rate under the standard frosting conditionEnergy and Built Environment, 2024
- Air source heat pump in-situ performanceEnergy and Buildings, 2021
- Impact of installation faults in air conditioners and heat pumps in single-family homes on U.S. energy usageApplied Energy, 2020
- Smart homes, home energy management systems and real-time feedback: Lessons for influencing household energy consumption from a Swedish field studyEnergy and Buildings, 2018
- Review on improvement for air source heat pump units during frosting and defrostingApplied Energy, 2018
- A virtual thermostat for local temperature controlEnergy and Buildings, 2016
- Optimum placement of top discharge outdoor unit installed near a wallEnergy and Buildings, 2013
- Thermostat strategies impact on energy consumption in residential buildingsEnergy and Buildings, 2011
- Simulation of the effects of duct leakage and heat transfer on residential space-cooling energy useEnergy and Buildings, 1993