Practical Chart for Harmonic Resonance Assessment of DFIG-Based Wind Parks
- 7 January 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (5) , 2233-2242
Abstract
Harmonic resonances in DFIG-based wind parks can be investigated by using extensive electromagnetic transient simulations, which is a time-consuming process. This paper shows that not all wind parks need such a detailed analysis. In response, the paper proposes a practical, easy-to-use method for a first-cut assessment of the risk of harmonic resonance of DFIG-based wind parks. First, simple equations are obtained to estimate resonance frequency and amplification in terms of wind park parameters readily available in practice. These equations reveal combinations of wind park parameters that cause problematic resonance. Such combinations are used to trace regions of concern in a chart. If the wind park is out of all regions of concern of the chart, one can directly declare this park is resonance-free, without running any simulation study. In addition to the analytic (model-based) method, a measurement-based method is provided for obtaining the resonance chart without running any simulation. Examples show how the proposed approach can be applied to facilitate resonance assessment during the wind park planning and operation.Keywords
Funding Information
- São Paulo Research Foundation (#2018/24018-0, #2016/08645-9)
- Office of International Affairs and External Cooperation of the University of Costa Rica (OAICE-CAB-165-2016)
- National Council for Scientific and Technological Development (432347/2018-6)
This publication has 12 references indexed in Scilit:
- Impedance Modeling of Three-Phase Voltage Source Converters in DQ, Sequence, and Phasor DomainsIEEE Transactions on Energy Conversion, 2017
- Safe Operation of DFIG-Based Wind Parks in Series-Compensated SystemsIEEE Transactions on Power Delivery, 2017
- Harmonic Assessment for Wind Parks Based on Sensitivity AnalysisIEEE Transactions on Sustainable Energy, 2017
- Analysis of the Behavior of Undamped and Unstable High-Frequency Resonance in a DFIG SystemIEEE Transactions on Power Electronics, 2017
- Overview of DFIG-Based Wind Power System Resonances Under Weak NetworksIEEE Transactions on Power Electronics, 2016
- Resonance-Free Shunt Capacitors—Configurations, Design Methods and Comparative AnalysisIEEE Transactions on Power Delivery, 2015
- A Refined Frequency Scan Approach to Sub-Synchronous Control Interaction (SSCI) Study of Wind FarmsIEEE Transactions on Power Systems, 2015
- Extended Harmonic Domain Model of a Wind Turbine Generator for Harmonic Transient AnalysisIEEE Transactions on Power Delivery, 2015
- Reactive compensation systems for large wind farms2008
- Low-Frequency Characterization of Switched dc-dc ConvertersIEEE Transactions on Aerospace and Electronic Systems, 1973