Experimental and numerical analysis of the performance of the R290 rotary compressor used in a split-room air conditioner at high ambient temperature

Authors:

Abstract
To respond to new energy efficiency standards and environmentally friendly policies in hot climate regions, it is necessary to develop high-efficiency air conditioners. The environmentally friendly and favourable thermo-physical properties of R290 and the high efficiency of rotary compressors have led to the proposal of R290 rotary compressors for use in split-room air conditioners in hot climate regions. The performance of R290 rotary compressor at high temperatures requires in-depth research. In this study, an R290 rotary compressor was experimentally and numerically studied at different ambient temperatures (ta = 35 °C, 46 °C, and 55 °C), using different oils (mineral oil (MO) and synthetic oil (SO)). The results show that the volumetric efficiency (ηv) and adiabatic efficiency (ηad) of the R290 rotary compressor decrease by only 5% and 6%, respectively, from ta = 35 °C to 55 °C; even at 55 °C, ηv and ηad are 89% and 67%, respectively, while the decrements of the R32 rotary compressor both reached more than 10%. In addition, the R290 rotary compressor performance differs with different oils because of miscibility, solubility, and viscosity influences on leakage and friction losses.
Funding Information
  • National Natural Science Foundation of China (51676147)
  • HCFC phase-out management plan in room air conditioning sector technical assistance fund (C/III/S16/154)

This publication has 18 references indexed in Scilit: