Actively shielded capacitive proximity sensor for endoscopy
Open Access
- 1 September 2023
- journal article
- research article
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 9 (1) , 93-96
Abstract
Flexible endoscopes are widely used for diagnostic and therapeutic procedures on internal organs and tissue surfaces. Accurate positioning of the endoscope tip is critical for obtaining clear images and avoiding tissue damage. Proximity sensors can provide information about the distance to the surrounding tissue, which can help align the endoscope tip and navigate along curved paths. This paper presents a method of proximity measurement using capacitive sensors with active shielding to determine the radial distance between an endoscope and surrounding tissue. The capacitive sensor consists of four copper foil electrodes attached to a 9.5 mm diameter ring. Two different active shielding designs were investigated and compared to reduce the sensing angle and minimize lateral effects. Capacitance was measured as a function of distance using a linear stage. A MATLAB script controlled the linear stage and calculated the distance from the measured capacitance. The results showed that advanced active shielding could be useful to reduce the sensing angle (angular space where capacitance sensor detects capacitance changes.). This method provides a cost-effective solution for radial distance measurement in endoscopy, essential for improving diagnostic and therapeutic procedures.Keywords
This publication has 9 references indexed in Scilit:
- Impact of the fiber cutting angle on fiber optic proximity sensors in endoscopyCurrent Directions in Biomedical Engineering, 2022
- Capacitive Proximity Sensor for Non-Contact Endoscope Localization2022
- Single-use endoscopes: A narrative reviewInternational Journal of Gastrointestinal Intervention, 2022
- Finding the curved pathway of the large intestine for robot-aided colonoscopyCurrent Directions in Biomedical Engineering, 2021
- An Optical Colon Contour Tracking System for Robot-aided Colonoscopy2021
- Endoscope localization and gastrointestinal feature map construction based on monocular SLAM technologyJournal of Infection and Public Health, 2020
- Distance control of soft robot using proximity sensor for beating heart surgery2016
- Image-based flexible endoscope steering2010
- Sensor-based guidance control of a continuum robot for a semi-autonomous colonoscopyRobotics and Autonomous Systems, 2009