Abstract
Temperature estimation in proton resonance frequency (PRF) shift MR thermometry requires a reference, or pretreatment, phase image that is subtracted from image phase during thermal treatment to yield a phase difference image proportional to temperature change. Referenceless thermometry methods derive a reference phase image from the treatment image itself by assuming that in the absence of a hot spot, the image phase can be accurately represented in a smooth (usually low order polynomial) basis. By masking the hot spot out of a least squares (ℓ2) regression, the reference phase image's coefficients on the polynomial basis are estimated and a reference image is derived by evaluating the polynomial inside the hot spot area. Referenceless methods are therefore insensitive to motion and bulk main field shifts, however, currently these methods require user interaction or sophisticated tracking to ensure that the hot spot is masked out of the polynomial regression. This article introduces an approach to reference PRF shift thermometry that uses reweighted ℓ1 regression, a form of robust regression, to obtain background phase coefficients without hot spot tracking and masking. The method is compared to conventional referenceless thermometry, and demonstrated experimentally in monitoring HIFU heating in a phantom and canine prostate, as well as in a healthy human liver. Magn Reson Med, 2010.Keywords
This publication has 16 references indexed in Scilit:
- Real‐time MR thermometry for monitoring HIFU ablations of the liverMagnetic Resonance in Medicine, 2009
- Method for Target Tracking in Focused Ultrasound Surgery of Liver using Magnetic Resonance Filtered Venography2007
- Optimization of self-reference thermometry using complex field estimationMagnetic Resonance in Medicine, 2006
- Referenceless PRF shift thermometryMagnetic Resonance in Medicine, 2004
- Real‐time cardiac MRI at 3 teslaMagnetic Resonance in Medicine, 2004
- Ex vivo tissue‐type independence in proton‐resonance frequency shift MR thermometryMagnetic Resonance in Medicine, 1998
- Minimum Lp-norm two-dimensional phase unwrappingJournal of the Optical Society of America A, 1996
- A precise and fast temperature mapping using water proton chemical shiftMagnetic Resonance in Medicine, 1995
- Noninvasive MRI Thermometry with the Proton Resonance Frequency (PRF) Method: In Vivo Results in Human MuscleMagnetic Resonance in Medicine, 1995