Effect of acquisition parameters on the accuracy of velocity encoded cine magnetic resonance imaging blood flow measurements
Open Access
- 7 January 2002
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 15 (1) , 47-54
Abstract
Purpose: To investigate the effect of acquisition parameters on the accuracy of 2D velocity encoded cine magnetic resonance imaging (VEC MRI) flow measurements.Materials and Methods: Using a pulsatile flow phantom, through‐plane flow measurements were performed on a flexible vessel made of polyvinyl alcohol cryogel (PVA), a material that mimics the MR signal and biomechanical properties of aortic tissue.Results: Repeated VEC MRI flow measurements (N = 20) under baseline conditions yielded an error of 0.8 ± 1.5%. Slice thickness, angle between flow and velocity encoding directions, spatial resolution, velocity encoding range, and radio frequency (RF) flip angles were varied over a clinically relevant range. Spatial resolution had the greatest impact on accuracy, with a 9% overestimation of flow at 16 pixels per vessel cross‐section.Conclusion: VEC MRI proved to be an accurate and reproducible technique for pulsatile flow measurements over the range of acquisition parameters examined as long as sufficient spatial resolution was prescribed. J. Magn. Reson. Imaging 2002;15:47–54.Keywords
This publication has 39 references indexed in Scilit:
- Phase-Velocity Cine Magnetic Resonance Imaging Measurement of Pulsatile Blood Flow in Children and Young Adults: In Vitro and In Vivo ValidationPediatric Cardiology, 2000
- MR BLOOD FLOW MEASUREMENTCardiology Clinics, 1998
- Accuracy of MR phase contrast velocity measurements for unsteady flowJournal of Magnetic Resonance Imaging, 1995
- Dynamic nature of the aortic regurgitant orifice area during diastole in patients with chronic aortic regurgitation.Circulation, 1994
- Magnetic Resonance Imaging of Blood Flow with a Phase Subtraction TechniqueInvestigative Radiology, 1993
- MR measurement of blood flow in the cardiovascular system.American Journal of Roentgenology, 1992
- Noninvasive blood flow measurement and quantification of shunt volume by cine magnetic resonance in congenital heart diseasePediatric Radiology, 1992
- Right and left ventricular stroke volume measurements with velocity-encoded cine MR imaging: in vitro and in vivo validation.American Journal of Roentgenology, 1991
- Human abdominal aorta: comparative measurements of blood flow with MR imaging and multigated Doppler US.Radiology, 1989
- Quantitative flow measurements on phantoms and on blood vessels with MRMagnetic Resonance in Medicine, 1988