Abstract
Electrical parameters such as total equivalent capacitance, dielectric capacitance, and average discharge power of a dielectric barrier discharge (DBD)-cold atmospheric plasma (CAP) setup have been determined and their dependency on the applied voltage, air gap, and ground arrangement have been investigated. Considering a more practical scenario of DBD-CAP application in material processing and biomedical fields, three different ground arrangements: (i) bare ground, (ii) glass slide covered ground and (iii) water in a petri dish on the ground electrode have been considered in this study. The electrical parameters are determined by interpreting the charge-voltage (Q-V) plot of the DBD-CAP obtained experimentally. The value of effective dielectric capacitance (ζ d ) determined from Q-V plot at a lower applied voltage is less, and approaches the geometrically calculated value (C d ) at higher applied voltage which signifies the DBD discharge occurs from the partial area of the electrode surface. Discharge power and discharge efficiency increase with the applied voltage (V a ). Empirical fit of the obtained discharge power shows the increase is proportional to ( V a − B ) 2 , where the value of constant B is close to the value of threshold voltage for the discharge.
Funding Information
  • Indian Council of Medical Research (5/3/8/85/2020-ITR dated 06/01/2021)

This publication has 37 references indexed in Scilit: