Rapid 2D variable flip angle method for accurate and precise T1 measurements over a wide range of T1 values
Authors:
Open Access
- 24 May 2021
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 34 (8) , e4542
Abstract
Purpose: To perform dynamic T1 mapping using a 2D variable flip angle (VFA) method, a correction for the slice profile effect is needed. In this work we investigated the impact of flip angle selection and excitation RF pulse profile on the performance of slice profile correction when applied to T1 mapping over a range of T1 values.Methods: A correction of the slice profile effect is proposed, based on Bloch simulation of steady‐state signals. With this correction, Monte Carlo simulations were performed to assess the accuracy and precision of 2D VFA T1 mapping in the presence of noise, for RF pulses with time‐bandwidth products of 2, 3 and 10 and with flip angle pairs in the range [1°‐90°]. To evaluate its performance over a wide range of T1, maximum errors were calculated for six T1 values between 50 ms and 1250 ms. The method was demonstrated using in vitro and in vivo experiments.Results: Without corrections, 2D VFA severely underestimates T1. Slice profile errors were effectively reduced with the correction based on simulations, both in vitro and in vivo. The precision and accuracy of the method depend on the nominal T1 values, the FA pair, and the RF pulse shape. FA pairs leading to T1 can be identified for the common RF shapes, for T1 values between 50 ms and 1250 ms.Conclusions: 2D VFA T1 mapping with Bloch‐simulation‐based correction can deliver T1 estimates that are accurate and precise to within 5% over a wide T1 range.Keywords
Funding Information
- KWF Kankerbestrijding
- Stichting voor de Technische Wetenschappen
This publication has 30 references indexed in Scilit:
- Transmit field inhomogeneity and T1estimation errors in breast DCE‐MRI at 3 teslaJournal of Magnetic Resonance Imaging, 2013
- Optimal radiofrequency and gradient spoiling for improved accuracy of T1 and B1 measurements using fast steady‐state techniquesMagnetic Resonance in Medicine, 2010
- Gleaning multicomponent T1 and T2 information from steady‐state imaging dataMagnetic Resonance in Medicine, 2008
- Linear least‐squares method for unbiased estimation of T1 from SPGR signalsMagnetic Resonance in Medicine, 2008
- MR thermometryJournal of Magnetic Resonance Imaging, 2008
- Actual flip‐angle imaging in the pulsed steady state: A method for rapid three‐dimensional mapping of the transmitted radiofrequency fieldMagnetic Resonance in Medicine, 2006
- Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heartMagnetic Resonance in Medicine, 2004
- Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady stateMagnetic Resonance in Medicine, 2003
- Inversion recovery image reconstruction with multiseed region‐growing spin reversalJournal of Magnetic Resonance Imaging, 1996
- Spin‐lattice relaxation time measurement by means of a TurboFLASH techniqueMagnetic Resonance in Medicine, 1993