High-Sensitivity Measurement of Density by Magnetic Levitation
- 11 February 2016
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (5) , 2666-2674
Abstract
This paper presents methods that use Magnetic Levitation (MagLev) to measure very small differences in density of solid diamagnetic objects suspended in a paramagnetic medium. Previous work in this field has shown that, while it is a convenient method, standard MagLev (i.e., where the direction of magnetization and gravitational force are parallel) cannot resolve differences in density mm) because (i) objects close in density prevent each other from reaching an equilibrium height due to hard contact and excluded volume, and (ii) using weaker magnets or reducing the magnetic susceptibility of the medium destabilizes the magnetic trap. The present work investigates the use of weak magnetic gradients parallel to the faces of the magnets as a means of increasing the sensitivity of MagLev without destabilization. Configuring the MagLev device in a rotated state (i.e., where the direction of magnetization and gravitational force are perpendicular) relative to the standard configuration enables simple measurements along the axes with the highest sensitivity to changes in density. Manipulating the distance of separation between the magnets or the lengths of the magnets (along the axis of measurement) enables the sensitivity to be tuned. These modifications enable an improvement in the resolution up to 100-fold over the standard configuration, and measurements with resolution down to 10–6 g/cm3. Three examples of characterizing the small differences in density among samples of materials having ostensibly indistinguishable densities—Nylon spheres, PMMA spheres, and drug spheres—demonstrate the applicability of rotated Maglev to measuring the density of small (0.1–1 mm) objects with high sensitivity. This capability will be useful in materials science, separations, and quality control of manufactured objects.Keywords
Funding Information
- Agency for Science, Technology and Research
- Bill and Melinda Gates Foundation (51308)
- Office of Naval Research
- Transient Electronics, Inc.
This publication has 46 references indexed in Scilit:
- Evaluation of a Density-Based Rapid Diagnostic Test for Sickle Cell Disease in a Clinical Setting in ZambiaPLOS ONE, 2014
- Density-based separation in multiphase systems provides a simple method to identify sickle cell diseaseProceedings of the National Academy of Sciences, 2014
- Biodiesel Density: Experimental Measurements and Prediction ModelsEnergy & Fuels, 2011
- Nondestructive Testing of Food Quality2007
- Using experimental design to optimise precision of steam distillation for determining alcoholic strength in spiritsEuropean Food Research and Technology, 2005
- Measurement of density and chemical concentration using a microfluidic chipLab on a Chip, 2003
- Practical Density Measurement and Hydrometry2002
- The Density of Hydrous Magmatic LiquidsScience, 1999
- In Situ Observations of a High-Pressure Phase of H 2 O IceScience, 1998
- Continuous blood density measurement for hemodynamic monitoring: An analysis of its accuracy and sensitivityAnnals of Biomedical Engineering, 1993