Design, fabrication, installation, and testing of high energy sweeper

Authors:

Abstract
A room temperature high-energy sweeper had been designed, fabricated, and installed at the postacceleration section of the Tandem accelerator. The sweeper, a part of the new pulsing system, is being used to inject the bunched beam without dark current into the linear accelerator acting as a booster of the Tandem. The resonance frequency of the sweeper was set at 6.0625MHz and a quality factor of ∼1300 was achieved. During off-line testing of the sweeper, a deflector voltage of ∼30kV had been measured for an input power of 300W . A pair of indigenously fabricated capacitors is used for fine-tuning of the resonance frequency. The silver plated coil of the tank circuit was fabricated with two concentric copper tubes. During the successful beam test of the sweeper, a peak to dark current ratio of 97% has been achieved.

This publication has 4 references indexed in Scilit: