Design, fabrication, installation, and testing of high energy sweeper
Authors:
- 1 July 2006
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 77 (7) , 076103
Abstract
A room temperature high-energy sweeper had been designed, fabricated, and installed at the postacceleration section of the Tandem accelerator. The sweeper, a part of the new pulsing system, is being used to inject the bunched beam without dark current into the linear accelerator acting as a booster of the Tandem. The resonance frequency of the sweeper was set at and a quality factor of was achieved. During off-line testing of the sweeper, a deflector voltage of had been measured for an input power of . A pair of indigenously fabricated capacitors is used for fine-tuning of the resonance frequency. The silver plated coil of the tank circuit was fabricated with two concentric copper tubes. During the successful beam test of the sweeper, a peak to dark current ratio of 97% has been achieved.
Keywords
This publication has 4 references indexed in Scilit:
- First on-line test of the LINAC superbuncher at nuclear science centrePramana, 2002
- Testing and operation of the 15UD Pelletron at NSCNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993
- Multipurpose Beam Pulsing System for the 12UD Pelletron Tandem Accelerator at the University of TsukubaJapanese Journal of Applied Physics, 1983
- A theory on obtaining short bursts of ions from a beam of ionsNuclear Instruments and Methods, 1960