Effect of curing method and thermocycling on flexural strength and microhardness of a new composite resin with alkaline filler
Open Access
- 1 January 2021
- journal article
- research article
- Published by Medknow in Dental Research Journal
- Vol. 18 (1) , 96
Abstract
Background: Cention N has been introduced as an alternative material for amalgam. The purpose was to investigate the flexural strength and microhardness of this material in self-cure and dual-cure modes before and after thermocycling. Materials and Methods: In this experimental study, 40 samples of Cention N were prepared in order to determine and compare the microhardness. Half of the samples were set by self-cure method and the other half with dual-cure method. The Vickers microhardness test was performed once after 24 h and again after 10000 thermocyclings. Three-point flexural test was used to determine and compare the flexural strength of 52 rod-shaped samples. Half of the samples were set by self-cure method and the other half with dual-cure method. Among 26 samples in each group, 13 samples were randomly selected and three-point flexural test was performed after 24 h and for another 13 samples after 10,000 thermocyclings. Data were analyzed using two-way ANOVA and paired samples t-test (P < 0.05). Results: There was a statistically significant difference between the mean of microhardness values in two curing methods (P < 0.001) and in two storage conditions (P < 0.001). The mean of dual-cure microhardness (100.99 ± 7.22) was higher than that of self-cure (64.61 ± 12.51) and the mean value associated with pre-thermocycling (89.75 ± 15.84) was higher than that of the post-thermocycling (76.44 ± 23.56). There was no statistically significant difference between the mean flexural strength in the two curing methods (self-cure [72.85 ± 16.26], dual cure [79.87 ± 23.07]; [P > 0.05]). However, the mean flexural strength without thermocycling (85.98 ± 21.74) was higher than that of the thermocycled group (64.24 ± 6.40) (P < 0.001). Conclusion: The microhardness of Cention N in dual-cure mode was higher than that of self-cure mode, but the flexural strength of dual-cure was not significantly different from that of self-cure. Thermocycling had a significant effect on the microhardness and flexural strength.Keywords
This publication has 15 references indexed in Scilit:
- Marginal Integrity of Bulk Versus Incremental Fill Class II Composite RestorationsOperative Dentistry, 2016
- Comparing marginal microleakage of three Bulk Fill composites in Class II cavities using confocal microscope: An in vitro studyJournal of Conservative Dentistry, 2015
- Effect of Thermocycling on Flexural Strength and Weibull Statistics of Machinable Glass–Ceramic and Composite ResinThe Journal of Indian Prosthodontic Society, 2013
- The Effect of a Modeling Resin and Thermocycling on the Surface Hardness, Roughness, and Color of Different Resin CompositesJournal of Esthetic and Restorative Dentistry, 2013
- Surface hardness evaluation of different composite resin materials: influence of sports and energy drinks immersion after a short-term periodJournal of Applied Oral Science, 2013
- Flexural properties of resin composites: Influence of specimen dimensions and storage conditionsDental Materials Journal, 2013
- Effect of thermocycling on the flexural and impact strength of urethane‐based and high‐impact denture base resinsGerodontology, 2011
- The effect of clinically relevant thermocycling on the flexural properties of endodontic post materialsJournal of Dentistry, 2010
- Conversion Degree of Indirect Resin Composites and Effect of Thermocycling on Their Physical PropertiesJournal of Prosthodontics, 2010
- The effects of thermocycling on the flexural strength and flexural modulus of modern resin-based filling materialsDental Materials, 2006