The COSMED K5 in Breath-by-Breath and Mixing Chamber Mode at Low to High Intensities
Authors:
- 31 December 2019
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 52 (5) , 1153-1162
Abstract
Purpose: The portable metabolic analyzer COSMED K5 (Rome, Italy) allows for switching between breath-by-breath (BBB) and dynamic micro-mixing chamber (DMC) modes. This study aimed to evaluate the reliability and validity of the K5 in BBB and DMC at low, moderate, and high metabolic rates. Methods: Two K5 simultaneously operated in BBB or DMC, whereas (i) a metabolic simulator (MS) produced four different metabolic rates (repeated eight times), and (ii) 12 endurance-trained participants performed bike exercise at 30%, 40%, 50%, and 85% of their individual power output at V˙O2max (repeated three times). K5 data were compared with predicted simulated values and consecutive Douglas bag measurements. Results: Reliability did not differ significantly between BBB and DMC, whereas the typical error and intraclass correlation coefficients for oxygen uptake (V˙O2), carbon dioxide output (V˙CO2), and minute ventilation (V˙E) ranged from 0.27% to 6.18% and from 0.32 to 1.00 within four metabolic rates, respectively. Validity indicated by mean differences ranged between 0.61% and −2.05% for V˙O2, 2.99% to −11.04% for V˙CO2, and 0.93% to −6.76% for V˙E compared with MS and Douglas bag at low to moderate metabolic rates and was generally similar for MS and bike exercise. At high rates, mean differences for V˙O2 amounted to −4.63% to −7.27% in BBB and −0.38% to −3.81% in DMC, indicating a significantly larger difference of BBB at the highest metabolic rate. Conclusion: The K5 demonstrated accurate to acceptable reliability in BBB and DMC at all metabolic rates. Validity was accurate at low and moderate metabolic rates. At high metabolic rates, BBB underestimated V˙O2, whereas DMC showed superior validity. To test endurance athletes at high workloads, the DMC mode is recommended.Keywords
This publication has 39 references indexed in Scilit:
- Validity, reliability and stability of the portable Cortex Metamax 3B gas analysis systemEuropean Journal of Applied Physiology, 2011
- Validity and reliability of the Cortex MetaMax3B portable metabolic systemJournal of Sports Sciences, 2010
- Validity and reliability of selected commercially available metabolic analyzer systemsScandinavian Journal of Medicine & Science in Sports, 2005
- Gas Exchange Measurements with High Temporal Resolution: The Breath-by-Breath ApproachInternational Journal of Sports Medicine, 2004
- Performance Characteristics of Gas Analysis Systems: What We Know and What We Need to KnowInternational Journal of Sports Medicine, 2004
- Validity and Stability of a Computerized Metabolic System with Mixing ChamberInternational Journal of Sports Medicine, 2004
- Validation of the MetaMax II Portable Metabolic Measurement SystemInternational Journal of Sports Medicine, 2004
- Validation of a Computerized Metabolic Measurement System (Oxycon-Pro®) During Low and High Intensity Exercise1International Journal of Sports Medicine, 2001
- Automated Metabolic Gas Analysis SystemsSports Medicine, 2001
- Pulmonary Mechanics and Entrainment of Respiration and Stroke Rate During RowingInternational Journal of Sports Medicine, 1993