Removing uranium from drinking water by metal hydroxides and anion‐exchange resin
Authors:
- Suk Y. LeeSLSuk Y. Lee
- Ernest A. BondiettiEBErnest A. Bondietti
- 1 October 1983
- journal article
- research article
- Published by Wiley in Journal AWWA
- Vol. 75 (10) , 536-540
Abstract
Results of bench‐scale testing on uranium removal from a natural water that was chosen as a good representative of uranium‐bearing waters indicated that conventional coagulant and lime softening treatment removes more than 85 percent of dissolved uranium (83 μg U/L) when an optimum pH and dosage were provided. A strong base anion‐exchange column is a recommended option for the treatment of private well waters containing uranium at higher than desirable levels.Keywords
This publication has 4 references indexed in Scilit:
- Removing uranium by current municipal water treatment processesJournal AWWA, 1983
- Treatment Technology to Meet the Interim Primary Drinking Water Regulations for Inorganics: Part 5Journal AWWA, 1980
- Uranium solution-mineral equilibria at low temperatures with applications to sedimentary ore depositsGeochimica et Cosmochimica Acta, 1978
- Radium‐Removal Efficiencies in Water‐Treatment ProcessesJournal AWWA, 1978